PAYNE HEATING AND COOLING / AIR-SOURCE HEAT PUMP

PH8TAN548**AA*

2-STAGE 18 SEER HP

148 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity46,000–50,500BTU/h

Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 148 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18148 / 148
EER2 · BTU/Wh11.7–13.5148 / 148
HSPF2 · BTU/Wh7.8–8.5148 / 148
Cooling capacity · BTU/h46,000–50,500148 / 148
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500148 / 148
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,400148 / 148
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600148 / 148
COP at 5°F / −15°C2.1–2.32148 / 148
Equipment / loop typeHP - Split System148 / 148
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)148 / 148
Compressor stagingTwo-stage148 / 148
Connected capabilityNo148 / 148

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
PF5TNBD60L*AHRI reference: 21556071618.008.10246002.32EPA 3982810 →
CVAMA4921XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562331317.508.10244002.14EPA 3947639 →
CVAMA6021XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562371117.508.10244002.14EPA 3948272 →
CVAVA4924XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562446917.508.10246002.14EPA 3948707 →
CVAVA6121XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562504117.508.10250002.12EPA 3949251 →
CVAVA6121XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562506017.508.50244002.30EPA 3949272 →
CVAVA6121XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562507917.508.50250002.26EPA 3949289 →
CVAVA6121XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562515617.508.10246002.14EPA 3949456 →
CVAVA6124XMA*+ furnace: PG80VTLB66135D**AHRI reference: 21562551917.508.50250002.26EPA 3949639 →
CVAVA6124XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562550117.508.50248002.28EPA 3949836 →
CVAMA4821XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562295617.008.10240002.14EPA 3947361 →
CVAMA4921XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562329417.008.10250002.12EPA 3947618 →
CVAMA4921XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562333217.008.10248002.10EPA 3947657 →
CVAMA4921XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562339317.008.10250002.10EPA 3947719 →
CVAMA4921XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562340917.008.10248002.12EPA 3947733 →
CVAMA4921XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562354217.008.10252002.10EPA 3947852 →
CVAVA4821XMA*+ furnace: PG80MSUA60080C**AHRI reference: 21562409617.008.10240002.14EPA 3948089 →
CVAMA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562369217.008.10250002.10EPA 3948182 →
CVAMA6021XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562373017.008.10248002.10EPA 3948293 →
CVAMA6021XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562379117.008.10246002.12EPA 3948350 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.