XH624E2S11
LX SERIES · source records, page 3
157 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 157 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 157 / 157 |
| EER2 · BTU/Wh | 11.7–12 | 157 / 157 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 157 / 157 |
| Cooling capacity · BTU/h | 22,800–24,200 | 157 / 157 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,600–24,000 | 157 / 157 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,500–15,500 | 157 / 157 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,900–12,800 | 157 / 157 |
| COP at 5°F / −15°C | 2–2.3 | 157 / 157 |
| Equipment / loop type | HP - Split System | 157 / 157 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 157 / 157 |
| Compressor staging | Two-stage | 157 / 157 |
| Connected capability | No | 157 / 157 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF30C5ACS1+ furnace: Z8ET120C20LMPS1AHRI reference: 217017040 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4572046 → |
CTF30C5ACS1+ furnace: Z9ET100C16SMPS1AHRI reference: 217017025 | 16.00 | 7.80 | 12400 | 2.10 | EPA 4572050 → |
CTF30C5ACS1+JMET12CS2N1AHRI reference: 217017001 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4572055 → |
CTF30C5ACS1+JMET16CS2N1AHRI reference: 217016985 | 16.00 | 7.80 | 12300 | 2.16 | EPA 4572058 → |
CTF30B5ACS1+JME12B2SN1AHRI reference: 217016961 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572065 → |
CTU30B5XCS1+JMC12B2SN1+TXVAHRI reference: 217016930 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572074 → |
CTF30B5ACS1+JMC12B2SN1AHRI reference: 217016929 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572075 → |
CTU30B5XCS1+JMVT12BC2N1+TXVAHRI reference: 217016928 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572076 → |
CTF30B5ACS1+JMVT12BC2N1AHRI reference: 217016927 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572077 → |
CTF30C5ACS1+JME12C2SN1AHRI reference: 217016914 | 16.00 | 7.80 | 12200 | 2.16 | EPA 4572080 → |
CTF30C5ACS1+JME16C2SN1AHRI reference: 217016910 | 16.00 | 7.80 | 12200 | 2.16 | EPA 4572083 → |
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 217016834 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572101 → |
JHE30B5AD2SS2AHRI reference: 218457222 | 16.00 | 8.10 | 12100 | 2.26 | EPA 4639464 → |
JHE24B5AC2SS2AHRI reference: 218457216 | 16.00 | 8.00 | 12000 | 2.12 | EPA 4639470 → |
CTM36B5ADS2+ furnace: Z8ES100B12LMPS1AHRI reference: 218528510 | 16.00 | 8.10 | 12500 | 2.26 | EPA 4647556 → |
CTM36B5ADS2+ furnace: Z8ES100B12SMPS1AHRI reference: 218528506 | 16.00 | 8.10 | 12500 | 2.26 | EPA 4647560 → |
CTM36B5ADS2+ furnace: Z8ET080B12LMPS1AHRI reference: 218528502 | 16.00 | 8.10 | 12400 | 2.26 | EPA 4647564 → |
CTM30B5ACS2+ furnace: Z8ES100B12LMPS1AHRI reference: 218528472 | 16.00 | 7.80 | 12500 | 2.10 | EPA 4647578 → |
CTM30B5ACS2+ furnace: Z8ES100B12SMPS1AHRI reference: 218528468 | 16.00 | 7.80 | 12500 | 2.10 | EPA 4647582 → |
CTM30B5ACS2+JMC12B2SN1AHRI reference: 218528454 | 16.00 | 7.80 | 12200 | 2.12 | EPA 4647586 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →