Luxaire / AIR-SOURCE HEAT PUMP

XH624E2S11

LX SERIES · source records, page 4

157 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,800–24,200BTU/h

Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 157 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16157 / 157
EER2 · BTU/Wh11.7–12157 / 157
HSPF2 · BTU/Wh7.8–8.1157 / 157
Cooling capacity · BTU/h22,800–24,200157 / 157
Heating capacity at 47°F / 8.3°C · BTU/h22,600–24,000157 / 157
Heating capacity at 17°F / −8.3°C · BTU/h14,500–15,500157 / 157
Heating capacity at 5°F / −15°C · BTU/h11,900–12,800157 / 157
COP at 5°F / −15°C2–2.3157 / 157
Equipment / loop typeHP - Split System157 / 157
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)157 / 157
Compressor stagingTwo-stage157 / 157
Connected capabilityNo157 / 157

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM30B5ACS2+JMVT12BC2N1AHRI reference: 21852844616.007.80122002.12EPA 4647590
CTU36B5XDS2+TXV+ furnace: Z9ET080B12SMPS1AHRI reference: 21852837816.008.10124002.24EPA 4647634
CTF36B5ADS2+ furnace: Z9ET080B12SMPS1AHRI reference: 21852837416.008.10124002.24EPA 4647638
CTU36B5XDS2+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21852836816.008.10125002.28EPA 4647644
CTU36B5XDS2+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21852836416.008.10125002.28EPA 4647648
CTF36B5ADS2+ furnace: Z8ES100B12LMPS1AHRI reference: 21852835816.008.10125002.28EPA 4647654
CTF36B5ADS2+ furnace: Z8ES100B12SMPS1AHRI reference: 21852835416.008.10125002.28EPA 4647658
CTU36B5XDS2+TXV+ furnace: Z8ES080B12LMPS1AHRI reference: 21852833616.008.10124002.28EPA 4647676
CTU36B5XDS2+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21852833216.008.10124002.28EPA 4647680
CTF36B5ADS2+ furnace: Z8ES080B12LMPS1AHRI reference: 21852832616.008.10124002.28EPA 4647686
CTF36B5ADS2+ furnace: Z8ES080B12SMPS1AHRI reference: 21852832216.008.10124002.28EPA 4647690
CTU36B5XDS2+TXV+ furnace: Z9ES080B12SMPS1AHRI reference: 21852831616.008.10124002.24EPA 4647696
CTF36B5ADS2+ furnace: Z9ES080B12SMPS1AHRI reference: 21852831016.008.10124002.24EPA 4647702
CTU36B5XDS2+JMC12B2SN1+TXVAHRI reference: 21852830616.008.10123002.30EPA 4647706
CTF36B5ADS2+JMC12B2SN1AHRI reference: 21852830216.008.10123002.30EPA 4647710
CTU36B5XDS2+JMVT12BC2N1+TXVAHRI reference: 21852829816.008.10123002.30EPA 4647714
CTF36B5ADS2+JMVT12BC2N1AHRI reference: 21852829416.008.10123002.30EPA 4647718
CTU36B5XDS2+TXV+ furnace: Z8ET080B12LMPS1AHRI reference: 21852829016.008.10124002.28EPA 4647722
CTF36B5ADS2+ furnace: Z8ET080B12LMPS1AHRI reference: 21852828616.008.10124002.28EPA 4647726
CTU36B5XDS2+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 21852827416.008.10124002.28EPA 4647738

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →