XH624E2S11
LX SERIES · source records, page 2
157 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 157 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 157 / 157 |
| EER2 · BTU/Wh | 11.7–12 | 157 / 157 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 157 / 157 |
| Cooling capacity · BTU/h | 22,800–24,200 | 157 / 157 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,600–24,000 | 157 / 157 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,500–15,500 | 157 / 157 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,900–12,800 | 157 / 157 |
| COP at 5°F / −15°C | 2–2.3 | 157 / 157 |
| Equipment / loop type | HP - Split System | 157 / 157 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 157 / 157 |
| Compressor staging | Two-stage | 157 / 157 |
| Connected capability | No | 157 / 157 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU36B5XDS1+JME12B2SN1+TXVAHRI reference: 217019646 | 16.00 | 8.10 | 12300 | 2.30 | EPA 4013764 → |
JHC36B5AD2SS1AHRI reference: 217019645 | 16.00 | 8.10 | 12400 | 2.28 | EPA 4013765 → |
CTF36B5ADS1+JME12B2SN1AHRI reference: 217019647 | 16.00 | 8.10 | 12300 | 2.30 | EPA 4013766 → |
JHE30B5AD2SS1AHRI reference: 217019648 | 16.00 | 8.10 | 12100 | 2.26 | EPA 4013767 → |
CTU36B5XDS1+JMC12B2SN1+TXVAHRI reference: 217019649 | 16.00 | 8.10 | 12300 | 2.30 | EPA 4013768 → |
CTF36B5ADS1+JMC12B2SN1AHRI reference: 217019650 | 16.00 | 8.10 | 12300 | 2.30 | EPA 4013769 → |
CTU36B5XDS1+JMVT12BC2N1+TXVAHRI reference: 217019651 | 16.00 | 8.10 | 12300 | 2.30 | EPA 4013770 → |
CTU36B5XDS1+JME08B2SN1+TXVAHRI reference: 217019652 | 16.00 | 8.10 | 12000 | 2.26 | EPA 4013771 → |
CTF36B5ADS1+JME08B2SN1AHRI reference: 217019653 | 16.00 | 8.10 | 12000 | 2.26 | EPA 4013772 → |
CTF36B5ADS1+JMVT12BC2N1AHRI reference: 217019654 | 16.00 | 8.10 | 12300 | 2.30 | EPA 4013773 → |
CTM36B5ADS1+JME08B2SN1AHRI reference: 217019655 | 16.00 | 8.00 | 12000 | 2.26 | EPA 4013774 → |
CTM36B5ADS1+JME12B2SN1AHRI reference: 217019659 | 16.00 | 8.10 | 12200 | 2.28 | EPA 4013775 → |
CTF36B5ADS1+ furnace: Z8VT080B12SMPC1AHRI reference: 217445307 | 16.00 | 8.10 | 12400 | 2.28 | EPA 4045362 → |
CTU36B5XDS1+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 217445308 | 16.00 | 8.10 | 12400 | 2.28 | EPA 4045363 → |
JHE36B5AD2SS1AHRI reference: 217019661 | 16.00 | 8.10 | 12300 | 2.28 | EPA 4498105 → |
CTM30B5ACS1+JME12B2SN1AHRI reference: 217018825 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4571467 → |
CTM30B5ACS1+JMC12B2SN1AHRI reference: 217018821 | 16.00 | 7.80 | 12200 | 2.12 | EPA 4571468 → |
CTM30B5ACS1+JMVT12BC2N1AHRI reference: 217018820 | 16.00 | 7.80 | 12200 | 2.12 | EPA 4571469 → |
CTM30B5ACS1+ furnace: Z8ES100B12SMPS1AHRI reference: 217018816 | 16.00 | 7.80 | 12500 | 2.10 | EPA 4571470 → |
CTM30B5ACS1+ furnace: Z8ES100B12LMPS1AHRI reference: 217018813 | 16.00 | 7.80 | 12500 | 2.10 | EPA 4571471 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →