XH548E2S11
LX SERIES · source records, page 2
364 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 364 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 364 / 364 |
| EER2 · BTU/Wh | 11–12 | 364 / 364 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 364 / 364 |
| Cooling capacity · BTU/h | 44,500–48,000 | 364 / 364 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 364 / 364 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 364 / 364 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 364 / 364 |
| COP at 5°F / −15°C | 2.1–2.42 | 364 / 364 |
| Equipment / loop type | HP - Split System | 364 / 364 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 364 / 364 |
| Compressor staging | Two-stage | 364 / 364 |
| Connected capability | No | 364 / 364 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CHS1+ furnace: TMLE080C20MP11AHRI reference: 214429015 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559089 → |
CTM60C5CHS1+ furnace: TM8Y120C20MP11AHRI reference: 214429143 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559094 → |
JHC60C5CH2SS1AHRI reference: 214429310 | 15.20 | 8.10 | 26600 | 2.38 | EPA 3559104 → |
JSC48D5CG2SS1AHRI reference: 214833532 | 15.20 | 7.80 | 24800 | 2.26 | EPA 3560531 → |
JSE48D5CG2SS1AHRI reference: 214833537 | 15.20 | 7.80 | 24600 | 2.26 | EPA 3560536 → |
JHE48C5CG2SS1AHRI reference: 214424717 | 15.20 | 7.80 | 24800 | 2.10 | EPA 3627818 → |
CTF60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 215743026 | 15.20 | 7.80 | 26200 | 2.38 | EPA 3653152 → |
CTF60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 215743131 | 15.20 | 7.80 | 26000 | 2.40 | EPA 3653198 → |
CTF60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 215743043 | 15.20 | 7.80 | 26000 | 2.40 | EPA 3653201 → |
CTM60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 216437822 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815056 → |
CTM60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 216437827 | 15.20 | 7.80 | 26200 | 2.34 | EPA 3815061 → |
CTM60C5CHS1+ furnace: Z8ET080C16LMPS1AHRI reference: 216437832 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815066 → |
CTM60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 216437837 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3815071 → |
CTM60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 216437842 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815076 → |
CTM60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 216437847 | 15.20 | 8.00 | 25800 | 2.38 | EPA 3815081 → |
CTM60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 216437852 | 15.20 | 8.00 | 26400 | 2.36 | EPA 3815086 → |
CTM60D5CHS1+ furnace: Z9ET120D20SMPS1AHRI reference: 216437857 | 15.20 | 8.00 | 26600 | 2.36 | EPA 3815091 → |
CTM60C5CHS1+JME12C2SN1AHRI reference: 214431910 | 15.20 | 8.10 | 25800 | 2.42 | EPA 3892766 → |
CTM60C5CHS1+JMET12CS2N1AHRI reference: 214431932 | 15.20 | 7.80 | 25800 | 2.40 | EPA 3892768 → |
CTM60C5CHS1+JMET16CS2N1AHRI reference: 214426626 | 15.20 | 8.10 | 26400 | 2.40 | EPA 3892775 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →