XH548E2S11
LX SERIES
364 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 364 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 364 / 364 |
| EER2 · BTU/Wh | 11–12 | 364 / 364 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 364 / 364 |
| Cooling capacity · BTU/h | 44,500–48,000 | 364 / 364 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 364 / 364 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 364 / 364 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 364 / 364 |
| COP at 5°F / −15°C | 2.1–2.42 | 364 / 364 |
| Equipment / loop type | HP - Split System | 364 / 364 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 364 / 364 |
| Compressor staging | Two-stage | 364 / 364 |
| Connected capability | No | 364 / 364 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217444954 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4571147 → |
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217444952 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4571149 → |
CTM60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217444951 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4571150 → |
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217444949 | 16.00 | 7.80 | 26000 | 2.42 | EPA 4571152 → |
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217444948 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4571153 → |
CTM60C5CHS2+ furnace: Z8VT100C16SMPC1AHRI reference: 218517963 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4641600 → |
CTM60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218517959 | 16.00 | 7.80 | 26000 | 2.42 | EPA 4641604 → |
CTM60C5CHS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218517955 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4641608 → |
CTM60C5CHS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218517951 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4641612 → |
CTF60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218517285 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4642076 → |
CTF60C5CHS1+ furnace: TM8E120C20MP11AHRI reference: 214426959 | 15.20 | 7.80 | 26000 | 2.36 | EPA 3558367 → |
CTF60C5CHS1+ furnace: TMLE120C20MP11AHRI reference: 214426969 | 15.20 | 7.80 | 26000 | 2.36 | EPA 3558373 → |
JHE48D5CG2SS1AHRI reference: 214427354 | 15.20 | 7.80 | 24600 | 2.26 | EPA 3558478 → |
JHE60C5CH2SS1AHRI reference: 214427400 | 15.20 | 8.10 | 26400 | 2.40 | EPA 3558557 → |
CTM60D5CHS1+ furnace: TM8E130D20MP11AHRI reference: 214428212 | 15.20 | 7.80 | 27200 | 2.32 | EPA 3558950 → |
JHC60D5CH2SS1AHRI reference: 214428290 | 15.20 | 8.10 | 26400 | 2.42 | EPA 3558960 → |
JHE60D5CH2SS1AHRI reference: 214428295 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3558963 → |
CTM60C5CHS1+ furnace: TMLE080C20MP11AHRI reference: 214428445 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559028 → |
CTF60C5CHS1+ furnace: TM8Y100C16MP11AHRI reference: 214428680 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3559046 → |
JHC48D5CG2SS1AHRI reference: 214428761 | 15.20 | 7.80 | 24800 | 2.26 | EPA 3559056 → |