XH548E2S11
LX SERIES · source records, page 3
364 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 364 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 364 / 364 |
| EER2 · BTU/Wh | 11–12 | 364 / 364 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 364 / 364 |
| Cooling capacity · BTU/h | 44,500–48,000 | 364 / 364 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 364 / 364 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 364 / 364 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 364 / 364 |
| COP at 5°F / −15°C | 2.1–2.42 | 364 / 364 |
| Equipment / loop type | HP - Split System | 364 / 364 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 364 / 364 |
| Compressor staging | Two-stage | 364 / 364 |
| Connected capability | No | 364 / 364 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60D5CHS1+JME18D2SN1AHRI reference: 214426070 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892780 → |
CTM60D5CHS1+JMET18DS2N1AHRI reference: 214426636 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892786 → |
JHC48C5CG2SS1AHRI reference: 214426694 | 15.20 | 7.80 | 24800 | 2.26 | EPA 3892793 → |
CTM60C5CGS1+JME12C2SN1AHRI reference: 214427339 | 15.20 | 7.80 | 25200 | 2.30 | EPA 3892796 → |
CTM60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 214605360 | 15.20 | 8.10 | 26400 | 2.38 | EPA 3892820 → |
CTM60C5CHS1+ furnace: Z9ES080C20SMPS1AHRI reference: 214605220 | 15.20 | 7.80 | 26000 | 2.36 | EPA 3892831 → |
CTM60C5CHS1+ furnace: Z9ES100C16SMPS1AHRI reference: 214605225 | 15.20 | 7.80 | 26600 | 2.34 | EPA 3892836 → |
CTM60D5CHS1+ furnace: Z9ES120D20SMPS1AHRI reference: 214605260 | 15.20 | 7.80 | 26600 | 2.36 | EPA 3892838 → |
CTM60C5CHS1+ furnace: Z8ES100C16SMPS1AHRI reference: 214605285 | 15.20 | 8.10 | 26600 | 2.36 | EPA 3892846 → |
CTM60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 214605290 | 15.20 | 8.10 | 26400 | 2.40 | EPA 3892850 → |
CTM60D5CGS1+JMC20D2SN1AHRI reference: 214428611 | 15.20 | 7.80 | 25400 | 2.30 | EPA 3892851 → |
CTM60C5CHS1+JME16C2SN1AHRI reference: 214428616 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892857 → |
CTM60D5CHS1+JMC20D2SN1AHRI reference: 214428874 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892861 → |
CTM60C5CGS1+JME16C2SN1AHRI reference: 214429000 | 15.20 | 7.80 | 25400 | 2.30 | EPA 3892867 → |
CTM60C5CHS1+JMVT17CC2N1AHRI reference: 214429315 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3892872 → |
CTM60C5CHS1+JMC17C2SN1AHRI reference: 214429320 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3892877 → |
CTM60D5CGS1+JMVT20DC2N1AHRI reference: 214429360 | 15.20 | 7.80 | 25400 | 2.30 | EPA 3892881 → |
CTM60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 214605475 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3892911 → |
CTM60C5CHS1+ furnace: Z8ES080C16SMPS1AHRI reference: 214605480 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3892914 → |
CTM60D5CGS1+JME18D2SN1AHRI reference: 214427440 | 15.20 | 7.80 | 25400 | 2.30 | EPA 3892915 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.