HH836E2S11
LX SERIES · source records, page 13
927 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 927 / 927 |
| EER2 · BTU/Wh | 10–12 | 927 / 927 |
| HSPF2 · BTU/Wh | 8–9.5 | 927 / 927 |
| Cooling capacity · BTU/h | 31,600–35,000 | 927 / 927 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,400 | 927 / 927 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 927 / 927 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 927 / 927 |
| COP at 5°F / −15°C | 2–2.1 | 927 / 927 |
| Equipment / loop type | HP - Split System | 927 / 927 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 927 / 927 |
| Compressor staging | Continuously variable | 927 / 927 |
| Connected capability | No | 927 / 927 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5CFS2+ furnace: Z8ES080C20LMPS1AHRI reference: 218521697 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4643879 → |
CTM48C5CFS2+ furnace: Z8ES080C20SMPS1AHRI reference: 218521693 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4643883 → |
CTM48C5CFS2+ furnace: Z8ES080C16LMPS1AHRI reference: 218521689 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4643887 → |
CTM48C5CFS2+ furnace: Z8ES080C16SMPS1AHRI reference: 218521685 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4643891 → |
CTM48C5CFS2+ furnace: LP9C080C16MP13AHRI reference: 218521683 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4643893 → |
CTM48C5CFS2+ furnace: TP9C080C16MP13AHRI reference: 218521679 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4643897 → |
CTM48C5CFS2+ furnace: TM9V080C16MP12AHRI reference: 218521675 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4643901 → |
CTM48C5CFS2+ furnace: Z8ES100C20LMPS1AHRI reference: 218521671 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4643905 → |
CTM48C5CFS2+ furnace: Z8ES100C20SMPS1AHRI reference: 218521667 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4643909 → |
CTM48C5CFS2+JMC16C2SN1AHRI reference: 218521663 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4643913 → |
CTM48C5AFS2+JMC16C2SN1AHRI reference: 218521659 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4643917 → |
CTM48C5CFS2+JMVT16CC2N1AHRI reference: 218521655 | 19.00 | 9.00 | 25000 | 2.00 | EPA 4643921 → |
CTM48C5AFS2+JMVT16CC2N1AHRI reference: 218521651 | 19.00 | 9.00 | 25000 | 2.00 | EPA 4643925 → |
CTM48C5CFS2+JMC17C2SN1AHRI reference: 218521647 | 19.00 | 9.00 | 25000 | 2.00 | EPA 4643929 → |
CTM48C5AFS2+JMC17C2SN1AHRI reference: 218521643 | 19.00 | 9.00 | 25000 | 2.00 | EPA 4643933 → |
CTM48C5CFS2+JMVT17CC2N1AHRI reference: 218521639 | 19.00 | 9.00 | 25000 | 2.00 | EPA 4643937 → |
CTM48C5AFS2+JMVT17CC2N1AHRI reference: 218521635 | 19.00 | 9.00 | 25000 | 2.00 | EPA 4643941 → |
CTM48C5CFS2+ furnace: TL8E100C20UH11AHRI reference: 218521631 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4643945 → |
CTM48C5CFS2+ furnace: TL8E080C16UH11AHRI reference: 218521627 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4643949 → |
CTM48C5CFS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218521619 | 19.00 | 9.50 | 23400 | 2.00 | EPA 4643957 → |