Luxaire / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 12

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM48C5CFS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21852178119.009.50226002.00EPA 4643795 →
CTM48C5CFS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21852177719.009.00226002.00EPA 4643799 →
CTM48C5CFS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21852177319.009.00230002.00EPA 4643803 →
CTM48C5CFS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21852176919.009.00230002.00EPA 4643807 →
CTM48C5CFS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852176119.009.00254002.00EPA 4643815 →
CTM48C5CFS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852175719.009.00254002.00EPA 4643819 →
CTM48C5CFS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21852175319.009.00256002.00EPA 4643823 →
CTM48C5CFS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21852174919.009.00252002.00EPA 4643827 →
CTM48C5CFS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21852174519.009.00252002.00EPA 4643831 →
CTM48C5CFS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852174119.009.00252002.00EPA 4643835 →
CTM48C5CFS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852173719.009.00252002.00EPA 4643839 →
CTM48C5CFS2+ furnace: LP9C100C20MP13AHRI reference: 21852173119.009.00258002.00EPA 4643845 →
CTM48C5CFS2+ furnace: TP9C100C20MP13AHRI reference: 21852172719.009.00258002.00EPA 4643849 →
CTM48C5CFS2+ furnace: TM9V100C20MP12AHRI reference: 21852172319.009.00258002.00EPA 4643853 →
CTM48C5CFS2+ furnace: TM8V080C16MP12AHRI reference: 21852171919.009.00252002.00EPA 4643857 →
CTM48C5CFS2+ furnace: TM8V100C16MP12AHRI reference: 21852171519.009.00252002.00EPA 4643861 →
CTM48C5CFS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852171119.009.00258002.00EPA 4643865 →
CTM48C5CFS2+ furnace: LP9C100C16MP13AHRI reference: 21852170919.009.00252002.00EPA 4643867 →
CTM48C5CFS2+ furnace: TP9C100C16MP13AHRI reference: 21852170519.009.00252002.00EPA 4643871 →
CTM48C5CFS2+ furnace: TM9V100C16MP12AHRI reference: 21852170119.009.00252002.00EPA 4643875 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →