HH836E2S11
LX SERIES · source records, page 14
927 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 927 / 927 |
| EER2 · BTU/Wh | 10–12 | 927 / 927 |
| HSPF2 · BTU/Wh | 8–9.5 | 927 / 927 |
| Cooling capacity · BTU/h | 31,600–35,000 | 927 / 927 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,400 | 927 / 927 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 927 / 927 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 927 / 927 |
| COP at 5°F / −15°C | 2–2.1 | 927 / 927 |
| Equipment / loop type | HP - Split System | 927 / 927 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 927 / 927 |
| Compressor staging | Continuously variable | 927 / 927 |
| Connected capability | No | 927 / 927 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5CFS2+ furnace: Z9ET080C16SMPS1AHRI reference: 218521615 | 19.00 | 9.50 | 24200 | 2.00 | EPA 4643961 → |
CTM36C5CDS2+JMVT17CC2N1AHRI reference: 218521547 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4644029 → |
CTM36C5ADS2+JMVT17CC2N1AHRI reference: 218521543 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4644033 → |
CTM36C5CDS2+JMC16C2SN1AHRI reference: 218521403 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4644173 → |
CTM36C5ADS2+JMC16C2SN1AHRI reference: 218521399 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4644177 → |
CTM36C5CDS2+JMC17C2SN1AHRI reference: 218521363 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4644213 → |
CTM36C5ADS2+JMC17C2SN1AHRI reference: 218521359 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4644217 → |
CTM36C5CDS2+JMVT16CC2N1AHRI reference: 218521355 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4644221 → |
CTM36C5ADS2+JMVT16CC2N1AHRI reference: 218521351 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4644225 → |
CTM36C5CDS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218521347 | 19.00 | 8.50 | 24000 | 2.00 | EPA 4644229 → |
CTM36C5ADS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218521343 | 19.00 | 8.50 | 24000 | 2.00 | EPA 4644233 → |
CTM36C5CDS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218521339 | 19.00 | 9.00 | 23400 | 2.00 | EPA 4644237 → |
CTM36C5ADS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218521335 | 19.00 | 9.00 | 23400 | 2.00 | EPA 4644241 → |
CTM36C5CDS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218521331 | 19.00 | 8.50 | 23400 | 2.00 | EPA 4644245 → |
CTM36C5ADS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218521327 | 19.00 | 8.50 | 23400 | 2.00 | EPA 4644249 → |
CTM36C5CDS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218521323 | 19.00 | 9.00 | 22800 | 2.00 | EPA 4644253 → |
CTM36C5ADS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218521319 | 19.00 | 9.00 | 22800 | 2.00 | EPA 4644257 → |
CTM36C5CDS2+ furnace: Z8ET100C20LMPS1AHRI reference: 218521315 | 19.00 | 9.00 | 23200 | 2.00 | EPA 4644261 → |
CTM36C5ADS2+ furnace: Z8ET100C20LMPS1AHRI reference: 218521311 | 19.00 | 9.00 | 23200 | 2.00 | EPA 4644265 → |
CTM36C5CDS2+ furnace: Z8ET100C16LMPS1AHRI reference: 218521299 | 19.00 | 8.50 | 23800 | 2.00 | EPA 4644277 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →