Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-036-230A**

MERIT ML17XP1 Series · source records, page 4

799 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 799 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8799 / 799
EER2 · BTU/Wh12.2–14799 / 799
HSPF2 · BTU/Wh7.8–8.7799 / 799
Cooling capacity · BTU/h34,800–36,000799 / 799
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000799 / 799
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000799 / 799
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300799 / 799
COP at 5°F / −15°C2.06–2.36799 / 799
Equipment / loop typeHP - Split System799 / 799
Refrigerant / source-reported GWPR-410A (GWP:2088)799 / 799
Compressor stagingSingle stage799 / 799
Connected capabilityNo799 / 799

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CX35-48C+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21380496316.607.80170002.14EPA 2856773
CX35-48C+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21380496416.607.80168002.14EPA 2856774
CX35-48C+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21380496616.607.80170002.16EPA 2856776
CX35-48C+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21380496716.607.80168002.14EPA 2856777
CX35-48C+TDR+ furnace: ML196UH110XE60C*AHRI reference: 21380496816.607.80170002.18EPA 2856778
CX35-48C+TDR+ furnace: SL280UH090V60C*AHRI reference: 21380497216.608.00171002.14EPA 2856782
CX35-48C+TDR+ furnace: SL280UH090XV60C*AHRI reference: 21380497316.608.00170002.12EPA 2856783
CX35-48C+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21380497416.608.00171002.14EPA 2856784
CK40HT-42C-0*+TDR+ furnace: EL196UH110XE60C*AHRI reference: 21462386116.608.00178002.20EPA 3475572
CK40HT-42C-0*+TDR+ furnace: EL280UH110E60C*AHRI reference: 21462386316.608.10181002.24EPA 3475573
CK40HT-42C-0*+TDR+ furnace: EL280UH110XE60C*AHRI reference: 21462386416.608.10181002.24EPA 3475574
CK40HT-51/61C-0*+TDR+ furnace: EL280UH110E48C*AHRI reference: 21462393816.608.00171002.20EPA 3475727
CK40HT-51/61C-0*+TDR+ furnace: EL280UH110E60C*AHRI reference: 21462393916.608.10175002.24EPA 3475729
CK40HT-51/61C-0*+TDR+ furnace: EL280UH110XE60C*AHRI reference: 21462394016.608.10175002.24EPA 3475731
CK40HT-51/61C-0*+TDR+ furnace: ML180UH090E60C*AHRI reference: 21462394816.608.00174002.22EPA 3475741
CK40HT-51/61C-0*+TDR+ furnace: ML180UH110V60C*AHRI reference: 21462395016.608.10177002.22EPA 3475743
CK40HT-51/61C-0*+TDR+ furnace: ML296UH110XV60C*AHRI reference: 21462396116.608.00175002.22EPA 3475755
CK40HT-51/61C-0*+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21462396216.608.10177002.24EPA 3475756
CK40DT-48C-0*+TDR+ furnace: ML180DF110E60C*AHRI reference: 21462401116.608.70188002.34EPA 3476008
CK40HT-42C-0*+TDR+ furnace: ML180UH110V60C*AHRI reference: 21462387416.608.10182002.22EPA 3476034

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →