Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-036-230A**

MERIT ML17XP1 Series · source records, page 5

799 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 799 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8799 / 799
EER2 · BTU/Wh12.2–14799 / 799
HSPF2 · BTU/Wh7.8–8.7799 / 799
Cooling capacity · BTU/h34,800–36,000799 / 799
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000799 / 799
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000799 / 799
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300799 / 799
COP at 5°F / −15°C2.06–2.36799 / 799
Equipment / loop typeHP - Split System799 / 799
Refrigerant / source-reported GWPR-410A (GWP:2088)799 / 799
Compressor stagingSingle stage799 / 799
Connected capabilityNo799 / 799

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-42C-0*+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21462387816.608.00179002.20EPA 3476040 →
CK40HT-42C-0*+TDR+ furnace: ML196UH110XE60C*AHRI reference: 21462388316.608.00178002.20EPA 3476046 →
CK40HT-42C-0*+TDR+ furnace: ML296UH110XV60C*AHRI reference: 21462388516.608.10181002.24EPA 3476049 →
CK40HT-42C-0*+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21462388616.608.10180002.22EPA 3476052 →
CK40HT-42C-0*+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21462388916.608.10184002.22EPA 3476055 →
CK40CT-48C-0*+TDR+ furnace: ML180UH110E60C*AHRI reference: 21462409016.608.00170002.14EPA 3476246 →
CK40CT-36B-0*+TDR+ furnace: ML180UH090E48B*AHRI reference: 21462405616.607.80168002.14EPA 3476264 →
CK40CT-48C-0*+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21462409316.607.80168002.12EPA 3476266 →
CK40CT-36B-0*+TDR+ furnace: ML180UH090XE48B*AHRI reference: 21462405816.607.80168002.14EPA 3476267 →
CK40CT-48C-0*+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21462409416.607.80170002.14EPA 3476635 →
CK40CT-48C-0*+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21462409516.607.80168002.14EPA 3476646 →
CK40CT-48C-0*+TDR+ furnace: EL195UH100NE60C*AHRI reference: 21462407516.607.80170002.16EPA 3476653 →
CK40CT-48C-0*+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21462409716.607.80170002.16EPA 3476655 →
CK40CT-48C-0*+TDR+ furnace: EL196UH090XE48C*AHRI reference: 21462407616.607.80170002.16EPA 3476657 →
CK40CT-48C-0*+TDR+ furnace: EL196UH110XE60C*AHRI reference: 21462407716.607.80170002.18EPA 3476658 →
CK40CT-48C-0*+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21462409816.607.80168002.14EPA 3476660 →
CK40CT-48C-0*+TDR+ furnace: ML196UH110XE60C*AHRI reference: 21462409916.607.80170002.18EPA 3476671 →
CK40CT-48C-0*+TDR+ furnace: SL280UH090V60C*AHRI reference: 21462410316.608.00171002.14EPA 3476676 →
CK40CT-48C-0*+TDR+ furnace: SL280UH090XV60C*AHRI reference: 21462410416.608.00170002.12EPA 3476678 →
CK40CT-48C-0*+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21462410516.608.00171002.14EPA 3476680 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →