Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-036-230A**

MERIT ML17XP1 Series · source records, page 3

799 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 799 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8799 / 799
EER2 · BTU/Wh12.2–14799 / 799
HSPF2 · BTU/Wh7.8–8.7799 / 799
Cooling capacity · BTU/h34,800–36,000799 / 799
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000799 / 799
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000799 / 799
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300799 / 799
COP at 5°F / −15°C2.06–2.36799 / 799
Equipment / loop typeHP - Split System799 / 799
Refrigerant / source-reported GWPR-410A (GWP:2088)799 / 799
Compressor stagingSingle stage799 / 799
Connected capabilityNo799 / 799

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CRX35-48C-**-*+TDR+ furnace: ML180DF110E60C*AHRI reference: 21325803616.608.70188002.34EPA 2839507
C35-48C+TDR+TXV+ furnace: EL195UH100NE60C*AHRI reference: 21380490316.607.80170002.16EPA 2856713
C35-48C+TDR+TXV+ furnace: EL196UH090XE48C*AHRI reference: 21380490416.607.80170002.16EPA 2856714
C35-48C+TDR+TXV+ furnace: EL196UH110XE60C*AHRI reference: 21380490516.607.80170002.18EPA 2856715
C35-48C+TDR+TXV+ furnace: ML180UH110E60C*AHRI reference: 21380491816.608.00170002.14EPA 2856728
C35-48C+TDR+TXV+ furnace: ML193UH090XE48C*AHRI reference: 21380492116.607.80168002.12EPA 2856731
C35-48C+TDR+TXV+ furnace: ML193UH110XE60C*AHRI reference: 21380492316.607.80168002.14EPA 2856732
C35-48C+TDR+TXV+ furnace: ML193UH110XE48C*AHRI reference: 21380492216.607.80170002.14EPA 2856733
C35-48C+TDR+TXV+ furnace: ML196UH090XE48C*AHRI reference: 21380492516.607.80170002.16EPA 2856735
C35-48C+TDR+TXV+ furnace: ML196UH090XE60C*AHRI reference: 21380492616.607.80168002.14EPA 2856736
C35-48C+TDR+TXV+ furnace: ML196UH110XE60C*AHRI reference: 21380492716.607.80170002.18EPA 2856737
C35-48C+TDR+TXV+ furnace: SL280UH080NV60C*AHRI reference: 21380493016.607.80170002.12EPA 2856740
C35-48C+TDR+TXV+ furnace: SL280UH090V60C*AHRI reference: 21380493116.608.00171002.14EPA 2856741
C35-48C+TDR+TXV+ furnace: SL280UH090XV60C*AHRI reference: 21380493216.608.00170002.12EPA 2856742
C35-48C+TDR+TXV+ furnace: SL280UH100NV60C*AHRI reference: 21380493316.608.00171002.14EPA 2856744
CX35-48C+TDR+ furnace: EL195UH100NE60C*AHRI reference: 21380494416.607.80170002.16EPA 2856754
CX35-48C+TDR+ furnace: EL196UH110XE60C*AHRI reference: 21380494616.607.80170002.18EPA 2856755
CX35-48C+TDR+ furnace: EL196UH090XE48C*AHRI reference: 21380494516.607.80170002.16EPA 2856756
CX35-48C+TDR+ furnace: ML180UH110E60C*AHRI reference: 21380495916.608.00170002.14EPA 2856770
CX35-48C+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21380496216.607.80168002.12EPA 2856772

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →