Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-030-230A**

MERIT ML17XP1 Series · source records, page 6

524 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-030-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 524 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2524 / 524
EER2 · BTU/Wh12.2–13.5524 / 524
HSPF2 · BTU/Wh7.8–8.6524 / 524
Cooling capacity · BTU/h28,200–30,600524 / 524
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000524 / 524
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600524 / 524
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400524 / 524
COP at 5°F / −15°C1.96–2.38524 / 524
Equipment / loop typeHP - Split System524 / 524
Refrigerant / source-reported GWPR-410A (GWP:2088)524 / 524
Compressor stagingSingle stage524 / 524
Connected capabilityNo524 / 524

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
C35-36B+TDR+TXV+ furnace: ML180UH070XE36B*AHRI reference: 21294506816.008.10143002.26EPA 2633884 →
C35-30B+TDR+TXV+ furnace: ML180UH090XE48B*AHRI reference: 21294506616.008.00142002.22EPA 2633886 →
C35-36A+TDR+TXV+ furnace: ML180UH045XE36A*AHRI reference: 21294506716.008.10144002.28EPA 2633892 →
CX35-30B+TDR+ furnace: ML180UH090XE48B*AHRI reference: 21294507416.008.00142002.22EPA 2633899 →
CX35-36B+TDR+ furnace: ML180UH070XE36B*AHRI reference: 21294507616.008.10143002.26EPA 2633906 →
CX35-36A+TDR+ furnace: ML180UH045XE36A*AHRI reference: 21294507516.008.10144002.28EPA 2633918 →
CK40CT-30A-0*+TDR+ furnace: SL280UH060NV36A*AHRI reference: 21462373316.008.10143002.24EPA 3474265 →
CK40HT-30B-0*+TDR+ furnace: ML180UH090V48B*AHRI reference: 21462364416.008.00137002.08EPA 3475083 →
CK40HT-30B-0*+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21462364816.007.80136002.06EPA 3475092 →
CK40HT-30B-0*+TDR+ furnace: SL280UH090V48B*AHRI reference: 21462365716.008.00137002.08EPA 3475101 →
CK40CT-30B-0*+TDR+ furnace: EL280UH090XE48B*AHRI reference: 21462374416.008.00142002.22EPA 3475116 →
CK40CT-30B-0*+TDR+ furnace: EL280UH090E48B*AHRI reference: 21462374316.008.00142002.22EPA 3475124 →
CK40CT-30B-0*+TDR+ furnace: ML180UH090E48B*AHRI reference: 21462375316.008.00142002.22EPA 3475196 →
CK40CT-30B-0*+TDR+ furnace: ML180UH090XE48B*AHRI reference: 21462375516.008.00142002.22EPA 3475198 →
CK40CT-30B-0*+TDR+ furnace: SL280UH090V36B*AHRI reference: 21462376616.008.10143002.20EPA 3475219 →
CK40CT-36A-0*+TDR+ furnace: EL280UH045E36A*AHRI reference: 21462377416.008.10143002.28EPA 3475229 →
CK40CT-36A-0*+TDR+ furnace: EL280UH070XE36A*AHRI reference: 21462377616.008.10143002.26EPA 3475230 →
CK40CT-36A-0*+TDR+ furnace: EL280UH070E36A*AHRI reference: 21462377516.008.10143002.26EPA 3475231 →
CK40CT-36A-0*+TDR+ furnace: ML180UH030V36A*AHRI reference: 21462377716.008.10144002.28EPA 3475234 →
CK40CT-36A-0*+TDR+ furnace: ML180UH045E36A*AHRI reference: 21462377816.008.10144002.28EPA 3475235 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →