Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-030-230A**

MERIT ML17XP1 Series · source records, page 5

524 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-030-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 524 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2524 / 524
EER2 · BTU/Wh12.2–13.5524 / 524
HSPF2 · BTU/Wh7.8–8.6524 / 524
Cooling capacity · BTU/h28,200–30,600524 / 524
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000524 / 524
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600524 / 524
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400524 / 524
COP at 5°F / −15°C1.96–2.38524 / 524
Equipment / loop typeHP - Split System524 / 524
Refrigerant / source-reported GWPR-410A (GWP:2088)524 / 524
Compressor stagingSingle stage524 / 524
Connected capabilityNo524 / 524

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CX35-30B+TDR+ furnace: ML180UH090E48B*AHRI reference: 21004720016.008.00142002.22EPA 2461043
CX35-36A+TDR+ furnace: ML180UH070E36A*AHRI reference: 21004722816.008.10144002.28EPA 2461045
C35-36A+TDR+TXV+ furnace: ML180UH030V36A*AHRI reference: 21004683616.008.10144002.28EPA 2461487
C35-36B+TDR+TXV+ furnace: SL297UH040NV36B*AHRI reference: 21004691016.008.10144002.28EPA 2461499
CX35-36B+TDR+ furnace: ML180UH070E36B*AHRI reference: 21004724916.008.10143002.26EPA 2461536
C35-36A+TDR+TXV+ furnace: ML180UH070XE36A*AHRI reference: 21004684916.008.10144002.28EPA 2461539
C35-36A+TDR+TXV+ furnace: ML180UH070E36A*AHRI reference: 21004684216.008.10144002.28EPA 2461709
CBA38MV-030-230*+TDRAHRI reference: 21004691816.008.50150002.38EPA 2461713
C35-36A+TDR+TXV+ furnace: ML180UH070V36A*AHRI reference: 21004684516.008.10145002.28EPA 2461977
C35-36B+TDR+TXV+ furnace: SLP99UH070XV36B*AHRI reference: 21004691316.008.10145002.28EPA 2461984
CX35-30A+TDR+ furnace: SL280UH060NV36A*AHRI reference: 21004717016.008.10143002.24EPA 2461991
C35-36B+TDR+TXV+ furnace: ML193UH070XE36B*AHRI reference: 21004689216.008.10144002.28EPA 2462244
C35-36B+TDR+TXV+ furnace: SL280UH090V48B*AHRI reference: 21004690816.008.10144002.28EPA 2462245
CX35-30B+TDR+ furnace: EL280UH090E48B*AHRI reference: 21004718616.008.00142002.22EPA 2462271
CX35-36B+TDR+ furnace: SL280UH090V48B*AHRI reference: 21004726816.008.10144002.28EPA 2462283
CHX35-30B-**-*+TDR+ furnace: ML180UH090V48B*AHRI reference: 21086986616.008.00137002.08EPA 2467899
CHX35-30B-**-*+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21086986916.007.80136002.06EPA 2467901
CHX35-30B-**-*+TDR+ furnace: SL280UH090V48B*AHRI reference: 21086987816.008.00137002.08EPA 2467911
C35-36B+TDR+TXV+ furnace: EL297UH070XV36B*AHRI reference: 21319453916.008.10145002.28EPA 2633195
CX35-36B+TDR+ furnace: EL297UH070XV36B*AHRI reference: 21319446616.008.10145002.28EPA 2633770

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →