Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-030-230A**

MERIT ML17XP1 Series · source records, page 7

524 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-030-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 524 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2524 / 524
EER2 · BTU/Wh12.2–13.5524 / 524
HSPF2 · BTU/Wh7.8–8.6524 / 524
Cooling capacity · BTU/h28,200–30,600524 / 524
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000524 / 524
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600524 / 524
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400524 / 524
COP at 5°F / −15°C1.96–2.38524 / 524
Equipment / loop typeHP - Split System524 / 524
Refrigerant / source-reported GWPR-410A (GWP:2088)524 / 524
Compressor stagingSingle stage524 / 524
Connected capabilityNo524 / 524

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40CT-36A-0*+TDR+ furnace: ML180UH045V36A*AHRI reference: 21462377916.008.10144002.28EPA 3475237
CK40CT-36A-0*+TDR+ furnace: ML180UH045XE36A*AHRI reference: 21462378016.008.10144002.28EPA 3475239
CK40CT-36A-0*+TDR+ furnace: ML180UH070E36A*AHRI reference: 21462378116.008.10144002.28EPA 3475240
CK40CT-36A-0*+TDR+ furnace: ML180UH070XE36A*AHRI reference: 21462378316.008.10144002.28EPA 3475241
CK40CT-36A-0*+TDR+ furnace: ML180UH070V36A*AHRI reference: 21462378216.008.10145002.28EPA 3475242
CK40CT-36B-0*+TDR+ furnace: ML180UH070E36B*AHRI reference: 21462380116.008.10143002.26EPA 3475259
CK40CT-36B-0*+TDR+ furnace: EL297UH070XV36B*AHRI reference: 21462380016.008.10145002.28EPA 3475260
CK40CT-36B-0*+TDR+ furnace: ML180UH070XE36B*AHRI reference: 21462380416.008.10143002.26EPA 3475263
CK40CT-36B-0*+TDR+ furnace: ML180UH090V48B*AHRI reference: 21462380616.008.10145002.28EPA 3475431
CK40CT-36B-0*+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21462381016.008.10144002.28EPA 3475432
CK40CT-36B-0*+TDR+ furnace: SL280UH090V48B*AHRI reference: 21462381916.008.10144002.28EPA 3475509
CK40CT-36B-0*+TDR+ furnace: SL297UH040NV36B*AHRI reference: 21462382016.008.10144002.28EPA 3475510
CK40CT-36B-0*+TDR+ furnace: SLP99UH070XV36B*AHRI reference: 21462382216.008.10145002.28EPA 3475513
CBK45UHET-036-230-0*AHRI reference: 21486128516.008.50132002.14EPA 3553528
CK40CT-36B-0*+TDR+ furnace: EL296UH070XV36B*AHRI reference: 21572829116.008.10145002.28EPA 3649663
CBA25UHV-036-230-**AHRI reference: 21105629015.808.10134002.16EPA 2454783
CX35-36A+TDR+ furnace: SL280UH070XV36A*AHRI reference: 21004723515.808.10144002.26EPA 2454809
CHX35-36C-**-*+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21004709315.808.30147002.24EPA 2454879
CX35-36A+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21004721715.808.00144002.26EPA 2454887
C35-30B+TDR+TXV+ furnace: EL280UH090E36B*AHRI reference: 21004676915.808.10143002.24EPA 2454895

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →