Kenmore / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 17

405 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 405 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18405 / 405
EER2 · BTU/Wh11.7–13.5405 / 405
HSPF2 · BTU/Wh7.8–8.5405 / 405
Cooling capacity · BTU/h45,500–50,500405 / 405
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500405 / 405
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600405 / 405
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600405 / 405
COP at 5°F / −15°C2.06–2.32405 / 405
Equipment / loop typeHP - Split System405 / 405
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)405 / 405
Compressor stagingTwo-stage405 / 405
Connected capabilityNo405 / 405

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X60M12A*+ furnace: *80MSU0601716A*AHRI reference: 21563410216.007.80252002.20EPA 3954022 →
ESH5X60M12A*+ furnace: *96VTN0802120B*AHRI reference: 21563463116.008.00252002.20EPA 3954036 →
ESH5X60M12A*+ furnace: *96VTN1002120B*AHRI reference: 21563464916.008.00252002.25EPA 3954056 →
ESH5X60M12A*+ furnace: *96VTN1002122B*AHRI reference: 21563466416.008.00250002.25EPA 3954068 →
ESH5X60M12A*+ furnace: *96VTN1202422B*AHRI reference: 21563468216.008.00252002.25EPA 3954089 →
ESH5X60M12A*+ furnace: *80MSU0802120A*AHRI reference: 21563412116.008.00248002.25EPA 3954110 →
ESH5X60M12A*+ furnace: *80CTL0702120B*AHRI reference: 21563418416.008.00254002.20EPA 3954147 →
ESH5X60M12A*+ furnace: *80CTL0902120B*AHRI reference: 21563419816.008.00252002.25EPA 3954158 →
ESH5X60M12A*+ furnace: *80CTL1102120B*AHRI reference: 21563421216.008.00252002.25EPA 3954172 →
ESH5X60M12A*+ furnace: *80CTL1352422B*AHRI reference: 21563422616.008.00250002.25EPA 3954186 →
ESH5X60M12A*+ furnace: *80VTL0902120B*AHRI reference: 21563425916.008.00250002.25EPA 3954203 →
ESH5X60M12A*+ furnace: *80VTL1102122B*AHRI reference: 21563427516.008.00250002.25EPA 3954221 →
ESH5X60M12A*+ furnace: *97CMN1202422B*AHRI reference: 21563439616.008.00254002.20EPA 3954254 →
ESH5X60M12A*+ furnace: *96VSN0802120B*AHRI reference: 21563443616.008.00252002.20EPA 3954273 →
ESH5X60M12A*+ furnace: *96VSN1002120B*AHRI reference: 21563444916.008.00252002.20EPA 3954282 →
ESH5X60M12A*+ furnace: *96VSN1202422B*AHRI reference: 21563446216.008.00252002.25EPA 3954304 →
EA*5X60M24A*+ furnace: *97VTN1002122A*AHRI reference: 21572176716.008.00254002.22EPA 3981812 →
EA*5X61M21A*+ furnace: *80CSU0802120B*AHRI reference: 21572178016.008.00252002.26EPA 3981831 →
EA*5X61M21A*+ furnace: *80CSU1002120B*AHRI reference: 21572179416.008.00254002.25EPA 3981842 →
EA*5X61M21A*+ furnace: *97VTN0802120A*AHRI reference: 21572181116.008.00256002.20EPA 3981863 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →