Kenmore / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 18

405 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 405 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18405 / 405
EER2 · BTU/Wh11.7–13.5405 / 405
HSPF2 · BTU/Wh7.8–8.5405 / 405
Cooling capacity · BTU/h45,500–50,500405 / 405
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500405 / 405
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600405 / 405
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600405 / 405
COP at 5°F / −15°C2.06–2.32405 / 405
Equipment / loop typeHP - Split System405 / 405
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)405 / 405
Compressor stagingTwo-stage405 / 405
Connected capabilityNo405 / 405

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M21A*+ furnace: *97VTN1002120A*AHRI reference: 21572182716.008.00256002.20EPA 3981875 →
EA*5X48M21A*+ furnace: *97VTN1002122A*AHRI reference: 21572174016.008.00248002.24EPA 3982226 →
EA*5X60M24A*+ furnace: *80CSU0802120B*AHRI reference: 21572175316.008.00254002.20EPA 3982235 →
EA*5X61M24A*+ furnace: *97VTN1002122A*AHRI reference: 21572186916.008.00258002.20EPA 3982278 →
EVM5X60M21A*+ furnace: *80CSU1002120B*AHRI reference: 21572202616.008.00246002.12EPA 3982437 →
ESH5X60M12A*+ furnace: *97VTN1002122A*AHRI reference: 21571800316.008.00250002.25EPA 4000885 →
ESH5X60M12A*+ furnace: *97CMN1002122B*AHRI reference: 21563438216.008.00252002.25EPA 4000917 →
ESH5X60M12A*+ furnace: *97CMN0802120B*AHRI reference: 21563436816.008.00252002.20EPA 4000931 →
ESH5X60M12A*+ furnace: *80CSU0802120B*AHRI reference: 21571784916.007.80250002.20EPA 4001052 →
EA*5X48M21A*+ furnace: *80CSU0802120A*AHRI reference: 21563121415.508.10252002.22EPA 3951997 →
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21563125515.508.10250002.20EPA 3952009 →
EA*5X48M21A*+ furnace: *80CTL0702120B*AHRI reference: 21563136615.508.10254002.20EPA 3952210 →
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21563142715.508.10250002.20EPA 3952324 →
EA*5X48M21A*+ furnace: *95CSU0802120B*AHRI reference: 21563147215.508.10254002.20EPA 3952356 →
EA*5X48M21A*+ furnace: *97CMN0802120B*AHRI reference: 21563152815.508.10252002.22EPA 3952384 →
EA*5X48M21A*+ furnace: *97CMN1002122B*AHRI reference: 21563154215.508.10252002.20EPA 3952399 →
EA*5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 21563158215.508.10252002.22EPA 3952413 →
EA*5X48M21A*+ furnace: *95MSU0802120A*AHRI reference: 21563163015.508.10252002.20EPA 3952426 →
EA*5X48M21A*+ furnace: *96CTN1002122B*AHRI reference: 21563169315.508.10252002.20EPA 3952490 →
EA*5X48M21A*+ furnace: *96VTN1002120B*AHRI reference: 21563176815.508.10252002.20EPA 3952511 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →