Kenmore / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 16

405 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 405 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18405 / 405
EER2 · BTU/Wh11.7–13.5405 / 405
HSPF2 · BTU/Wh7.8–8.5405 / 405
Cooling capacity · BTU/h45,500–50,500405 / 405
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500405 / 405
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600405 / 405
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600405 / 405
COP at 5°F / −15°C2.06–2.32405 / 405
Equipment / loop typeHP - Split System405 / 405
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)405 / 405
Compressor stagingTwo-stage405 / 405
Connected capabilityNo405 / 405

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 21563315016.008.10264002.16EPA 3953545 →
EA*5X61M24A*+ furnace: *96CTN1002122B*AHRI reference: 21563316416.008.10266002.16EPA 3953560 →
EA*5X61M24A*+ furnace: *97CMN1002122B*AHRI reference: 21563303116.008.10266002.16EPA 3953604 →
EA*5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 21563308516.008.10262002.20EPA 3953640 →
EA*5X61M24A*+ furnace: *95MSU1002120A*AHRI reference: 21563312016.008.10260002.20EPA 3953657 →
ESH5X48M12A*+ furnace: *80VTL0902120B*AHRI reference: 21563354116.008.00250002.20EPA 3953677 →
ESH5X48M12A*+ furnace: *80VTL1102122B*AHRI reference: 21563355716.008.00250002.20EPA 3953692 →
EA*5X61M24A*+ furnace: OLV154F20AAHRI reference: 21563325916.008.10260002.20EPA 3953746 →
ESH5X48M12A*+ furnace: *80VSL0902120B*AHRI reference: 21563334216.008.00250002.20EPA 3953771 →
ESH5X48M12A*+ furnace: *80VSL1102122B*AHRI reference: 21563335516.008.00250002.20EPA 3953781 →
ESH5X48M12A*+ furnace: *80CTL1102120B*AHRI reference: 21563349416.008.00248002.20EPA 3953837 →
ESH5X48M12A*+ furnace: *80CTL1352422B*AHRI reference: 21563350816.008.00248002.20EPA 3953851 →
ESH5X48M12A*+ furnace: *96VTN1002120B*AHRI reference: 21563393116.008.00252002.20EPA 3953868 →
ESH5X48M12A*+ furnace: *96VTN1002122B*AHRI reference: 21563394616.008.00248002.25EPA 3953882 →
ESH5X60M12A*+ furnace: *80VSL0902120B*AHRI reference: 21563406016.008.00250002.25EPA 3953908 →
ESH5X60M12A*+ furnace: *96CTN0802120B*AHRI reference: 21563454616.008.00252002.20EPA 3953942 →
ESH5X60M12A*+ furnace: *96CTN1002122B*AHRI reference: 21563456016.008.00252002.25EPA 3953963 →
ESH5X60M12A*+ furnace: *96CTN1202422B*AHRI reference: 21563457416.008.00254002.20EPA 3953972 →
ESH5X60M12A*+ furnace: *80VSL1102122B*AHRI reference: 21563407316.008.00250002.25EPA 3953993 →
ESH5X60M12A*+ furnace: *80VSL1352422B*AHRI reference: 21563408616.008.00250002.25EPA 3954007 →