XH548E2S11
LX SERIES · source records, page 9
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2 | 192 / 192 |
| EER2 · BTU/Wh | 11–12 | 192 / 192 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 192 / 192 |
| Cooling capacity · BTU/h | 44,500–48,000 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,200 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,000 | 192 / 192 |
| COP at 5°F / −15°C | 2.1–2.42 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Two-stage | 192 / 192 |
| Connected capability | No | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60C5XGS1+JMVT16CC2N1+TXVAHRI reference: 214807976 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4572294 → |
CTU60C5XGS1+JMET16CS2N1+TXVAHRI reference: 214807920 | 15.20 | 7.80 | 25200 | 2.24 | EPA 4572299 → |
CTU60C5XGS1+JMC17C2SN1+TXVAHRI reference: 214807915 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4572304 → |
CTU60C5XGS1+JMVT17CC2N1+TXVAHRI reference: 214807910 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4572309 → |
CTU60D5XHS1+TXV+ furnace: TP9C120D20MP13AHRI reference: 214649982 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4572321 → |
CTU60D5XHS1+TXV+ furnace: TM9V120D20MP12AHRI reference: 214649966 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4572326 → |
CTU60D5XGS1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 214649861 | 15.20 | 7.80 | 25400 | 2.24 | EPA 4572331 → |
CTF60C5CGS1+ furnace: Z8ES120C16SMPS1AHRI reference: 214605873 | 15.20 | 7.80 | 25800 | 2.20 | EPA 4572336 → |
CTM60C5CGS1+ furnace: Z8ES120C16SMPS1AHRI reference: 214605868 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4572341 → |
CTF60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 214605863 | 15.20 | 7.80 | 25400 | 2.24 | EPA 4572346 → |
CTM60D5CGS1+ furnace: Z8ES130D20SMPS1AHRI reference: 214605778 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4572351 → |
CTM60C5CGS1+ furnace: Z8ES100C16SMPS1AHRI reference: 214605688 | 15.20 | 7.80 | 26000 | 2.26 | EPA 4572356 → |
CTF60D5CGS1+ furnace: Z8ES130D20SMPS1AHRI reference: 214605428 | 15.20 | 7.80 | 25400 | 2.24 | EPA 4572371 → |
CTM60C5CGS1+ furnace: Z8ES080C20SMPS1AHRI reference: 214605408 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4572376 → |
CTF60C5CHS1+ furnace: Z9ES080C16SMPS1AHRI reference: 214605268 | 15.20 | 7.80 | 26800 | 2.30 | EPA 4572386 → |
CTM60C5CHS1+ furnace: Z9ES100C20SMPS1AHRI reference: 214605253 | 15.20 | 8.00 | 26400 | 2.36 | EPA 4572391 → |
CTF60C5CHS1+ furnace: Z9ES100C20SMPS1AHRI reference: 214605248 | 15.20 | 7.80 | 27000 | 2.30 | EPA 4572396 → |
CTM60C5CHS1+ furnace: Z9ES080C16SMPS1AHRI reference: 214605243 | 15.20 | 7.80 | 26200 | 2.34 | EPA 4572401 → |
CTF60C5CHS1+ furnace: Z9ES100C16SMPS1AHRI reference: 214605233 | 15.20 | 7.80 | 26600 | 2.32 | EPA 4572406 → |
CTM60C5CGS1+JMET16CS2N1AHRI reference: 214429368 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4572421 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.