Johnson Controls / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 10

192 published source records · source checked Sep 21, 2026

SEER2 range15.2BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2192 / 192
EER2 · BTU/Wh11–12192 / 192
HSPF2 · BTU/Wh7.8–8.1192 / 192
Cooling capacity · BTU/h44,500–48,000192 / 192
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000192 / 192
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,200192 / 192
Heating capacity at 5°F / −15°C · BTU/h24,600–27,000192 / 192
COP at 5°F / −15°C2.1–2.42192 / 192
Equipment / loop typeHP - Split System192 / 192
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)192 / 192
Compressor stagingTwo-stage192 / 192
Connected capabilityNo192 / 192

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CHS1+ furnace: TP9C100C20MP13AHRI reference: 21442884815.207.80270002.30EPA 4572425
CTM60C5CHS1+ furnace: TM9V100C20MP12AHRI reference: 21442884315.207.80270002.30EPA 4572430
CTM60C5CGS1+JMVT16CC2N1AHRI reference: 21442860915.207.80256002.28EPA 4572435
CTF60C5CGS1+JMC17C2SN1AHRI reference: 21442837015.207.80250002.26EPA 4572440
CTF60D5CHS1+ furnace: TP9C120D20MP13AHRI reference: 21442833315.207.80268002.34EPA 4572462
CTF60D5CHS1+ furnace: TM9V120D20MP12AHRI reference: 21442832815.207.80268002.34EPA 4572467
CTM60C5CHS1+ furnace: TM8V080C16MP12AHRI reference: 21442802815.207.80264002.34EPA 4572482
CTM60C5CHS1+ furnace: TM8V100C16MP12AHRI reference: 21442802315.207.80264002.34EPA 4572487
CTM60C5CHS1+ furnace: TL9E080C16UH11AHRI reference: 21442777915.207.80268002.30EPA 4572497
CTF60C5CGS1+JMC16C2SN1AHRI reference: 21442743315.207.80250002.26EPA 4572502
CTF60C5CGS1+JMVT16CC2N1AHRI reference: 21442742815.207.80250002.26EPA 4572507
CTF60C5CGS1+JMVT17CC2N1AHRI reference: 21442741815.207.80250002.26EPA 4572512