THF2B42T21
LX SERIES · source records, page 6
419 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 419 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 419 / 419 |
| EER2 · BTU/Wh | 11.7–12 | 419 / 419 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 419 / 419 |
| Cooling capacity · BTU/h | 39,500–42,000 | 419 / 419 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–41,000 | 419 / 419 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,200–26,600 | 419 / 419 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,400–22,600 | 419 / 419 |
| COP at 5°F / −15°C | 1.98–2.42 | 419 / 419 |
| Equipment / loop type | HP - Split System | 419 / 419 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 419 / 419 |
| Compressor staging | Two-stage | 419 / 419 |
| Connected capability | No | 419 / 419 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHD48FBCN1+ furnace: TM8Y100C16MP11AHRI reference: 210850357 | 16.00 | 8.10 | 19000 | 2.06 | EPA 3558096 → |
JHVTC42FBCC2N1AHRI reference: 211755656 | 16.00 | 8.10 | 19300 | 2.08 | EPA 3558149 → |
JHVTD42FBCC2N1AHRI reference: 211755700 | 16.00 | 8.10 | 19300 | 2.08 | EPA 3558185 → |
XAFC48FXXN1+JMET16CS2N1+TXVAHRI reference: 210851505 | 16.00 | 8.10 | 19900 | 2.06 | EPA 3624886 → |
XAFC48FXXN1+JMVT17CC2N1+TXVAHRI reference: 210848915 | 16.00 | 8.10 | 19300 | 2.08 | EPA 3624925 → |
XAFC48FXXN1+JMVT16CC2N1+TXVAHRI reference: 210845835 | 16.00 | 8.10 | 19300 | 2.08 | EPA 3624929 → |
XAFC48FXXN1+JMET12CS2N1+TXVAHRI reference: 210847740 | 16.00 | 8.10 | 19200 | 2.06 | EPA 3624947 → |
XAHC48FBCN1+ furnace: TM9V100C20MP12AHRI reference: 210847132 | 16.00 | 8.10 | 20200 | 2.12 | EPA 3989160 → |
XAHC48FBCN1+ furnace: TM8V100C20MP12AHRI reference: 210846688 | 16.00 | 8.10 | 20200 | 2.14 | EPA 3989210 → |
XAHC48FBCN1+ furnace: TM9V100C16MP12AHRI reference: 210851237 | 16.00 | 8.10 | 19000 | 2.08 | EPA 3989215 → |
XAHC48FBCN1+ furnace: TP9C100C16MP13AHRI reference: 210850326 | 16.00 | 8.10 | 19000 | 2.08 | EPA 3989267 → |
XAHD48FBCN1+JMVT20DC2N1AHRI reference: 210850336 | 16.00 | 8.10 | 19600 | 2.20 | EPA 3989271 → |
XAHD48FBCN1+ furnace: TL8E080C16UH11AHRI reference: 210848791 | 16.00 | 8.10 | 19300 | 2.08 | EPA 3989355 → |
XAHD48FBCN1+ furnace: TL9E080C16UH11AHRI reference: 210845369 | 16.00 | 8.10 | 19800 | 2.08 | EPA 3989362 → |
XAHC48FBCN1+ furnace: TM9Y080B12MP11AHRI reference: 210848779 | 16.00 | 7.80 | 19500 | 2.02 | EPA 3989386 → |
XAHD48FBCN1+ furnace: TM9V120D20MP12AHRI reference: 210848780 | 16.00 | 8.10 | 19900 | 2.14 | EPA 3989391 → |
XAHD48FBCN1+ furnace: TP9C100C16MP13AHRI reference: 210848174 | 16.00 | 8.10 | 19600 | 2.12 | EPA 3989397 → |
XAHC48FBCN1+ furnace: TL9E100C20UH11AHRI reference: 210848184 | 16.00 | 8.10 | 20400 | 2.12 | EPA 3989401 → |
XAFC48FBCN1+JMET16CS2N1AHRI reference: 210850464 | 16.00 | 8.10 | 19900 | 2.06 | EPA 3989420 → |
XAHD48FBCN1+ furnace: TM9E080C16MP12AHRI reference: 210850205 | 16.00 | 8.10 | 20800 | 2.10 | EPA 3989458 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →