Johnson Controls / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 5

419 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 419 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16419 / 419
EER2 · BTU/Wh11.7–12419 / 419
HSPF2 · BTU/Wh7.8–8.1419 / 419
Cooling capacity · BTU/h39,500–42,000419 / 419
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000419 / 419
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600419 / 419
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600419 / 419
COP at 5°F / −15°C1.98–2.42419 / 419
Equipment / loop typeHP - Split System419 / 419
Refrigerant / source-reported GWPR-410A (GWP:2088)419 / 419
Compressor stagingTwo-stage419 / 419
Connected capabilityNo419 / 419

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC60GBCN1+JMVT16CC2N1AHRI reference: 21327108916.008.10216002.40EPA 2840227
XAFD60GXXN1+JMET18DS4N1+TXVAHRI reference: 21327109516.008.10212002.32EPA 2840233
XAFD60GBCN1+JMET18DS2N1AHRI reference: 21327110216.008.10212002.34EPA 2840240
XAHC60GBCN1+JMET12CS2N1AHRI reference: 21327112316.008.10216002.38EPA 2840261
XAHC60GBCN1+JMVT17CC2N1AHRI reference: 21327113616.008.10216002.40EPA 2840283
XAFD60GXXN1+JMET18DS2N1+TXVAHRI reference: 21327115216.008.10212002.34EPA 2840290
XAFC60GBCN1+JMET16CS4N1AHRI reference: 21327115916.008.10212002.32EPA 2840298
XAHD60GBCN1+JMET18DS2N1AHRI reference: 21327120316.008.10220002.40EPA 2840342
XAFC60GBCN1+JMET16CS2N1AHRI reference: 21327121716.008.10216002.30EPA 2840357
XAFD60GXXN1+JMVT20DC2N1+TXVAHRI reference: 21327123716.008.10206002.34EPA 2840376
XAFC60GBCN1+JMVT17CC2N1AHRI reference: 21327124216.008.10208002.32EPA 2840381
XAHC60GBCN1+JMET16CS4N1AHRI reference: 21327126116.008.10220002.40EPA 2840400
XAHD48FBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21084582416.008.10202002.16EPA 3557977
XAHC48FBCN1+ furnace: TM8Y080B12MP11AHRI reference: 21084552416.008.10184002.02EPA 3558004
XAHC48FBCN1+ furnace: TM8Y100C16MP11AHRI reference: 21084684516.008.10204002.12EPA 3558044
XAHC48FBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21084693416.008.10202002.12EPA 3558047
XAHD48FBCN1+ furnace: TM8Y080C16MP11AHRI reference: 21084764816.008.10190002.06EPA 3558057
XAHD48FBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21084802716.008.10202002.16EPA 3558065
XAHC48FBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21084894216.008.10202002.12EPA 3558073
XAHC48FBCN1+ furnace: TM8Y080C16MP11AHRI reference: 21085150016.008.10190002.06EPA 3558092

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →