Johnson Controls / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 19

419 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 419 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16419 / 419
EER2 · BTU/Wh11.7–12419 / 419
HSPF2 · BTU/Wh7.8–8.1419 / 419
Cooling capacity · BTU/h39,500–42,000419 / 419
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000419 / 419
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600419 / 419
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600419 / 419
COP at 5°F / −15°C1.98–2.42419 / 419
Equipment / loop typeHP - Split System419 / 419
Refrigerant / source-reported GWPR-410A (GWP:2088)419 / 419
Compressor stagingTwo-stage419 / 419
Connected capabilityNo419 / 419

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD48FBCN1+ furnace: TM9E100C20MP12AHRI reference: 21085149915.208.10198002.12EPA 3990083 →
XAFC48FXXN1+TXV+ furnace: TM9Y080C16MP11AHRI reference: 21085149515.207.80196002.00EPA 3990084 →
XAFD48FBCN1+ furnace: TM9V120D20MP12AHRI reference: 21085159315.208.10196002.06EPA 3990109 →
XAFC48FBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21085159215.207.80196002.02EPA 3990110 →
XAHD48FBCN1+ furnace: TM9V080C16MP12AHRI reference: 21085168715.208.10193002.06EPA 3990128 →
XAHD60GBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 21247494015.208.10218002.36EPA 3990425 →
XAHD60GBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 21247495415.208.10218002.36EPA 3990433 →
XAHD60GBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21247498915.208.10220002.36EPA 3990445 →
XAHC48FBCN1+ furnace: Z9ET100C20SMPS1AHRI reference: 21241541115.207.80224002.30EPA 3990482 →
XAHC48FBCN1+ furnace: Z9ET080C16SMPS1AHRI reference: 21241550115.207.80222002.30EPA 3990487 →
XAHC60GBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21247721415.208.10220002.36EPA 3990508 →
XAHC60GBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247722115.208.10220002.36EPA 3990515 →
XAFC60GBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 21247723815.208.10212002.26EPA 3990520 →
XAFC60GBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21247725015.208.10212002.26EPA 3990527 →
XAFC60GBCN1+ furnace: Z8ES100B12SMPS1AHRI reference: 21247727415.208.10212002.24EPA 3990529 →
XAHC60GBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21248542815.208.10218002.32EPA 3990566 →
XAHC60GBCN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248543515.208.10218002.32EPA 3990567 →
XAFD60GBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21247506115.208.10212002.26EPA 3990581 →
XAHD60GBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247500315.208.10220002.36EPA 3990586 →
XAFD60GXXN1+TXV+ furnace: Z8ES100C20SMPS1AHRI reference: 21247501315.208.10212002.26EPA 3990592 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →