Johnson Controls / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 18

419 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 419 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16419 / 419
EER2 · BTU/Wh11.7–12419 / 419
HSPF2 · BTU/Wh7.8–8.1419 / 419
Cooling capacity · BTU/h39,500–42,000419 / 419
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000419 / 419
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600419 / 419
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600419 / 419
COP at 5°F / −15°C1.98–2.42419 / 419
Equipment / loop typeHP - Split System419 / 419
Refrigerant / source-reported GWPR-410A (GWP:2088)419 / 419
Compressor stagingTwo-stage419 / 419
Connected capabilityNo419 / 419

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD48FBCN1+ furnace: TP9C080C16MP13AHRI reference: 21085064615.208.10193002.06EPA 3989914 →
XAHC48FBCN1+ furnace: TM9E080B12MP12AHRI reference: 21085064815.208.10189002.02EPA 3989915 →
XAFD48FBCN1+ furnace: TL9E080C16UH11AHRI reference: 21085065615.207.80196002.00EPA 3989921 →
XAHC48FBCN1+ furnace: TM9Y100C20MP11AHRI reference: 21084581715.208.10202002.08EPA 3989928 →
XAFD48FBCN1+ furnace: TL9E100C20UH11AHRI reference: 21084583415.207.80199002.04EPA 3989930 →
XAFC48FXXN1+TXV+ furnace: TL8E100C20UH11AHRI reference: 21084669415.208.10196002.02EPA 3989944 →
XAHD48FBCN1+ furnace: TM8V100C16MP12AHRI reference: 21084681315.208.10204002.12EPA 3989973 →
XAHC48FBCN1+ furnace: TM9V080C16MP12AHRI reference: 21084680815.208.10193002.06EPA 3989974 →
XAFC48FBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21084681215.208.10196002.04EPA 3989975 →
XAHC48FBCN1+ furnace: TM8V080B12MP12AHRI reference: 21084681415.207.80189002.00EPA 3989977 →
XAFC48FBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21084683915.208.10196002.04EPA 3989983 →
XAHC48FBCN1+ furnace: TM9Y060B12MP11AHRI reference: 21084693115.207.80192002.00EPA 3989999 →
XAFD48FBCN1+ furnace: TM9E120D20MP12AHRI reference: 21084693315.208.10193002.04EPA 3990000 →
XAHC48FBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21084703815.208.10184002.02EPA 3990026 →
XAFD48FBCN1+ furnace: TM9V100C20MP12AHRI reference: 21084704015.207.80196002.04EPA 3990030 →
XAFD48FBCN1+ furnace: TP9C080C16MP13AHRI reference: 21084798115.207.80193002.00EPA 3990045 →
XAFC48FXXN1+TXV+ furnace: TM8Y120C20MP11AHRI reference: 21084798515.208.10196002.04EPA 3990048 →
XAFC48FXXN1+TXV+ furnace: TM8Y100C20MP11AHRI reference: 21084801115.208.10196002.04EPA 3990051 →
XAHC48FBCN1+ furnace: TM9Y080C16MP11AHRI reference: 21084808315.208.10186002.04EPA 3990062 →
XAFC48FXXN1+TXV+ furnace: TP9C100C16MP13AHRI reference: 21085149715.208.10195002.06EPA 3990081 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →