Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 844 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 844 / 844 |
| EER2 · BTU/Wh | 8.5–10.5 | 844 / 844 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 844 / 844 |
| Cooling capacity · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,200–27,000 | 844 / 844 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 844 / 844 |
| COP at 5°F / −15°C | 1.8–2.18 | 844 / 844 |
| Equipment / loop type | HP - Split System | 844 / 844 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 844 / 844 |
| Compressor staging | Continuously variable | 844 / 844 |
| Connected capability | No | 844 / 844 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFD48FBCN1+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 211397633 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2476281 → |
XAFD48FBCN1+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 211397618 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2476303 → |
XAHD48FBCN1+ furnace: TM8Y100C20MP11Cold climate designationAHRI reference: 211396505 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2476308 → |
XAHD48FBCN1+ furnace: TM9E100C16MP12Cold climate designationAHRI reference: 211395948 | 16.50 | 8.50 | 23200 | 2.02 | EPA 2476637 → |
XAFD48FBCN1+ furnace: TPLC100C16MP13Cold climate designationAHRI reference: 211397678 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2476651 → |
XAHB36DBCN1+ furnace: TM9V040A10MP12Cold climate designationAHRI reference: 211388478 | 16.50 | 8.10 | 23000 | 1.96 | EPA 2476775 → |
XAFD48FXXN1+TXV+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 211397561 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2476995 → |
XAHB36DXXN1+TXV+ furnace: TM9V040A10MP12Cold climate designationAHRI reference: 211388464 | 16.50 | 8.10 | 23000 | 1.96 | EPA 2477009 → |
XAHC48FXXN1+TXV+ furnace: TM9E100C16MP12Cold climate designationAHRI reference: 211395963 | 16.50 | 8.50 | 23200 | 2.02 | EPA 2477301 → |
XAFC48FXXN1+TXV+ furnace: TPLC100C16MP13Cold climate designationAHRI reference: 211397759 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2477615 → |
XAFC48FXXN1+TXV+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 211397705 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2477618 → |
XAFC48FXXN1+TXV+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 211397714 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2477641 → |
XAHB36DBCN1+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 211390544 | 16.50 | 8.10 | 23400 | 1.98 | EPA 2477683 → |
XAHB36DXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387746 | 16.50 | 8.10 | 23600 | 2.00 | EPA 2477824 → |
XAFC48FXXN1+TXV+ furnace: TPLC080C16MP13Cold climate designationAHRI reference: 211397744 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2478078 → |
XAHC48FBCN1+ furnace: TPLC100C16MP13Cold climate designationAHRI reference: 211397504 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2478090 → |
XAFD48FBCN1+ furnace: TPLC080C16MP13Cold climate designationAHRI reference: 211397663 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2478261 → |
XAHC48FXXN1+TXV+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 211397385 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2478327 → |
XAFC48FXXN1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 211395820 | 16.50 | 8.10 | 24000 | 2.04 | EPA 2478419 → |
XAHB36DBCN1+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211387775 | 16.50 | 8.10 | 23600 | 2.00 | EPA 2478469 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.