Johnson Controls / AIR-SOURCE HEAT PUMP

HMH72B341

HMH7 · source records, page 31

844 published source records · source checked Sep 21, 2026

SEER2 range15.5–18.5BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity31,400–35,200BTU/h

Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 844 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–18.5844 / 844
EER2 · BTU/Wh8.5–10.5844 / 844
HSPF2 · BTU/Wh8.1–8.5844 / 844
Cooling capacity · BTU/h31,400–35,200844 / 844
Heating capacity at 47°F / 8.3°C · BTU/h31,400–35,200844 / 844
Heating capacity at 17°F / −8.3°C · BTU/h24,200–27,000844 / 844
Heating capacity at 5°F / −15°C · BTU/h22,200–25,000844 / 844
COP at 5°F / −15°C1.8–2.18844 / 844
Equipment / loop typeHP - Split System844 / 844
Refrigerant / source-reported GWPR-410A (GWP:2088)844 / 844
Compressor stagingContinuously variable844 / 844
Connected capabilityNo844 / 844

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC48FBCN1+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 21139780816.508.50244002.10EPA 2474616 →
XAHC48FXXN1+TXV+ furnace: TM8V120C20MP12Cold climate designationAHRI reference: 21139705316.508.50238002.06EPA 2474622 →
XAFC48FBCN1+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 21139778616.508.50244002.10EPA 2474633 →
XAFC48FBCN1+ furnace: TM8Y120C20MP11Cold climate designationAHRI reference: 21139667116.508.50242002.10EPA 2474750 →
XAFD48FBCN1+ furnace: TM8Y100C20MP11Cold climate designationAHRI reference: 21139662616.508.50242002.10EPA 2474823 →
XAFC48FXXN1+TXV+ furnace: TM8Y120C20MP11Cold climate designationAHRI reference: 21139664116.508.50242002.10EPA 2474827 →
XAFD48FBCN1+ furnace: TM8Y120C20MP11Cold climate designationAHRI reference: 21139661716.508.50242002.10EPA 2474833 →
XAFC48FXXN1+TXV+ furnace: TM8Y100C20MP11Cold climate designationAHRI reference: 21139665616.508.50242002.10EPA 2474846 →
XAHC48FBCN1+ furnace: TPLC080C16MP13Cold climate designationAHRI reference: 21139748916.508.50238002.06EPA 2474873 →
XAHC48FXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21139621316.508.10234002.00EPA 2475052 →
XAFC48FXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21139625716.508.50238002.04EPA 2475062 →
XAHC48FBCN1+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 21139745116.508.50238002.06EPA 2475215 →
XAHB36DBCN1+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 21139055916.508.10234001.98EPA 2475723 →
XAHC48FBCN1+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21139623416.508.10234002.00EPA 2475725 →
XAFC48FBCN1+ furnace: TM8Y100C20MP11Cold climate designationAHRI reference: 21139669816.508.50242002.10EPA 2476118 →
XAHC48FXXN1+TXV+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 21139740016.508.50238002.06EPA 2476151 →
XAHD48FXXN1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 21139606116.508.10242002.04EPA 2476171 →
XAHD48FBCN1+ furnace: TM8E120C16MP11Cold climate designationAHRI reference: 21139813216.508.50232002.04EPA 2476184 →
XAHB36DXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21138775416.508.10236002.00EPA 2476197 →
XAHD48FBCN1+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 21139839716.508.50232002.02EPA 2476264 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →