HMH72B341
HMH7 · source records, page 31
844 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 844 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 844 / 844 |
| EER2 · BTU/Wh | 8.5–10.5 | 844 / 844 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 844 / 844 |
| Cooling capacity · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,200–27,000 | 844 / 844 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 844 / 844 |
| COP at 5°F / −15°C | 1.8–2.18 | 844 / 844 |
| Equipment / loop type | HP - Split System | 844 / 844 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 844 / 844 |
| Compressor staging | Continuously variable | 844 / 844 |
| Connected capability | No | 844 / 844 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFC48FBCN1+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 211397808 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2474616 → |
XAHC48FXXN1+TXV+ furnace: TM8V120C20MP12Cold climate designationAHRI reference: 211397053 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2474622 → |
XAFC48FBCN1+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 211397786 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2474633 → |
XAFC48FBCN1+ furnace: TM8Y120C20MP11Cold climate designationAHRI reference: 211396671 | 16.50 | 8.50 | 24200 | 2.10 | EPA 2474750 → |
XAFD48FBCN1+ furnace: TM8Y100C20MP11Cold climate designationAHRI reference: 211396626 | 16.50 | 8.50 | 24200 | 2.10 | EPA 2474823 → |
XAFC48FXXN1+TXV+ furnace: TM8Y120C20MP11Cold climate designationAHRI reference: 211396641 | 16.50 | 8.50 | 24200 | 2.10 | EPA 2474827 → |
XAFD48FBCN1+ furnace: TM8Y120C20MP11Cold climate designationAHRI reference: 211396617 | 16.50 | 8.50 | 24200 | 2.10 | EPA 2474833 → |
XAFC48FXXN1+TXV+ furnace: TM8Y100C20MP11Cold climate designationAHRI reference: 211396656 | 16.50 | 8.50 | 24200 | 2.10 | EPA 2474846 → |
XAHC48FBCN1+ furnace: TPLC080C16MP13Cold climate designationAHRI reference: 211397489 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2474873 → |
XAHC48FXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211396213 | 16.50 | 8.10 | 23400 | 2.00 | EPA 2475052 → |
XAFC48FXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211396257 | 16.50 | 8.50 | 23800 | 2.04 | EPA 2475062 → |
XAHC48FBCN1+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 211397451 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2475215 → |
XAHB36DBCN1+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 211390559 | 16.50 | 8.10 | 23400 | 1.98 | EPA 2475723 → |
XAHC48FBCN1+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211396234 | 16.50 | 8.10 | 23400 | 2.00 | EPA 2475725 → |
XAFC48FBCN1+ furnace: TM8Y100C20MP11Cold climate designationAHRI reference: 211396698 | 16.50 | 8.50 | 24200 | 2.10 | EPA 2476118 → |
XAHC48FXXN1+TXV+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 211397400 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2476151 → |
XAHD48FXXN1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211396061 | 16.50 | 8.10 | 24200 | 2.04 | EPA 2476171 → |
XAHD48FBCN1+ furnace: TM8E120C16MP11Cold climate designationAHRI reference: 211398132 | 16.50 | 8.50 | 23200 | 2.04 | EPA 2476184 → |
XAHB36DXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211387754 | 16.50 | 8.10 | 23600 | 2.00 | EPA 2476197 → |
XAHD48FBCN1+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211398397 | 16.50 | 8.50 | 23200 | 2.02 | EPA 2476264 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →