| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 844 / 844 |
| EER2 · BTU/Wh | 8.5–10.5 | 844 / 844 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 844 / 844 |
| Cooling capacity · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,200–27,000 | 844 / 844 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 844 / 844 |
| COP at 5°F / −15°C | 1.8–2.18 | 844 / 844 |
| Equipment / loop type | HP - Split System | 844 / 844 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 844 / 844 |
| Compressor staging | Continuously variable | 844 / 844 |
| Connected capability | No | 844 / 844 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFB36DXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211388883 | 17.50 | 8.10 | 24000 | 2.06 | EPA 2477488 → |
XAFB36DXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387883 | 17.50 | 8.50 | 23400 | 2.04 | EPA 2477551 → |
XAFC36DXXN1+TXV+ furnace: TP9C100C20MP13Cold climate designationAHRI reference: 211387321 | 17.50 | 8.10 | 24800 | 2.12 | EPA 2477557 → |
XAFC36DBCN1+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211387175 | 17.50 | 8.10 | 24200 | 2.04 | EPA 2477562 → |
XAFC36DXXN1+TXV+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 211390166 | 17.50 | 8.50 | 23800 | 2.08 | EPA 2477688 → |
XAFC48FBCN1+ furnace: TM8Y080C16MP11Cold climate designationAHRI reference: 211396954 | 17.50 | 8.50 | 24400 | 2.08 | EPA 2477884 → |
XAFB36DBCN1+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211388891 | 17.50 | 8.10 | 24000 | 2.06 | EPA 2477900 → |
XAFC36DBCN1+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 211387647 | 17.50 | 8.10 | 23800 | 2.08 | EPA 2477961 → |
XAFB36DBCN1+ furnace: TM8V060A12MP12Cold climate designationAHRI reference: 211391050 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2478125 → |
XAHC36DBCN1+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211388682 | 17.50 | 8.10 | 24400 | 2.06 | EPA 2478226 → |
XAHC36DBCN1+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211387093 | 17.50 | 8.10 | 23600 | 2.00 | EPA 2478425 → |
XAHB36DBCN1+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 211389672 | 17.50 | 8.10 | 23000 | 2.00 | EPA 2478445 → |
XAFB36DXXN1+TXV+ furnace: TMLV060A12MP12Cold climate designationAHRI reference: 211391020 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2478507 → |
XAFB36DXXN1+TXV+ furnace: TPLC060A12MP13Cold climate designationAHRI reference: 211391035 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2478518 → |
XAFC36DBCN1+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 211388258 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2478674 → |
XAHC36DBCN1+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 211389628 | 17.50 | 8.10 | 23200 | 2.02 | EPA 2478826 → |
XAHC36DBCN1+ furnace: TM8E120C16MP11Cold climate designationAHRI reference: 211391258 | 17.50 | 8.10 | 23200 | 2.04 | EPA 2478864 → |
XAFB36DXXN1+TXV+ furnace: TM8V060A12MP12Cold climate designationAHRI reference: 211391005 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2478874 → |
XAHB36DBCN1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 211391702 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2478897 → |
XAFD48FBCN1+ furnace: TM8Y100C16MP11Cold climate designationAHRI reference: 211396870 | 17.50 | 8.50 | 24400 | 2.08 | EPA 2479058 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.