Heating performance & equipment details
Ranges include the 844 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 844 / 844 |
| EER2 · BTU/Wh | 8.5–10.5 | 844 / 844 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 844 / 844 |
| Cooling capacity · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,200–27,000 | 844 / 844 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 844 / 844 |
| COP at 5°F / −15°C | 1.8–2.18 | 844 / 844 |
| Equipment / loop type | HP - Split System | 844 / 844 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 844 / 844 |
| Compressor staging | Continuously variable | 844 / 844 |
| Connected capability | No | 844 / 844 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFC36DBCN1+ furnace: TPLC100C16MP13Cold climate designationAHRI reference: 211390304 | 17.50 | 8.50 | 23800 | 2.08 | EPA 2475020 → |
XAFC36DXXN1+TXV+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 211390194 | 17.50 | 8.50 | 23800 | 2.08 | EPA 2475040 → |
XAHC36DBCN1+ furnace: TMLE080C16MP11Cold climate designationAHRI reference: 211392020 | 17.50 | 8.10 | 23200 | 2.04 | EPA 2475063 → |
XAHC36DBCN1+ furnace: TM8E080C16MP11Cold climate designationAHRI reference: 211392006 | 17.50 | 8.10 | 23200 | 2.04 | EPA 2475065 → |
XAHC36DBCN1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 211391617 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2475121 → |
XAFC36DBCN1+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211391542 | 17.50 | 8.10 | 23800 | 2.08 | EPA 2475134 → |
XAFC36DXXN1+TXV+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 211390180 | 17.50 | 8.50 | 23800 | 2.08 | EPA 2475539 → |
XAFB36DBCN1+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 211389094 | 17.50 | 8.10 | 24200 | 2.04 | EPA 2476126 → |
XAFC36DXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211388838 | 17.50 | 8.10 | 24400 | 2.06 | EPA 2476158 → |
XAFC36DXXN1+TXV+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 211387638 | 17.50 | 8.10 | 23800 | 2.08 | EPA 2476244 → |
XAHC36DXXN1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211388667 | 17.50 | 8.10 | 24400 | 2.06 | EPA 2476608 → |
XAFB36DXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211387897 | 17.50 | 8.50 | 23400 | 2.04 | EPA 2476860 → |
XAFC36DXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 211388228 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2476911 → |
XAFC36DBCN1+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211388853 | 17.50 | 8.10 | 24400 | 2.06 | EPA 2476921 → |
XAFC36DXXN1+TXV+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 211387520 | 17.50 | 8.50 | 24000 | 2.10 | EPA 2476940 → |
XAFC36DBCN1+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 211387654 | 17.50 | 8.10 | 23800 | 2.08 | EPA 2476949 → |
XAFB36DBCN1+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 211387026 | 17.50 | 8.50 | 23600 | 2.04 | EPA 2477002 → |
XAFB36DBCN1+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211387945 | 17.50 | 8.50 | 23400 | 2.04 | EPA 2477058 → |
XAFC36DXXN1+TXV+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 211387629 | 17.50 | 8.10 | 23800 | 2.08 | EPA 2477140 → |
XAFB30CXXN1+TXV+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211387245 | 17.50 | 8.10 | 23800 | 2.00 | EPA 2477324 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.