HL19B2421
MOMENTUM · source records, page 2
85 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HL19B2421. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–18 | 85 / 85 |
| EER2 · BTU/Wh | 11.7–14 | 85 / 85 |
| HSPF2 · BTU/Wh | 7.8 | 85 / 85 |
| Cooling capacity · BTU/h | 21,200–24,200 | 85 / 85 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–23,800 | 85 / 85 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 85 / 85 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,900–12,200 | 85 / 85 |
| COP at 5°F / −15°C | 1.8–2.06 | 85 / 85 |
| Equipment / loop type | HP - Split System | 85 / 85 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 85 / 85 |
| Compressor staging | Two-stage | 85 / 85 |
| Connected capability | No | 85 / 85 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFB36DBAN1+ furnace: TP9C080B12MP13AHRI reference: 210847524 | 17.00 | 7.80 | 10900 | 1.96 | EPA 2481433 → |
XAFB36DXXN1+TXV+ furnace: TL9E060B12UH11AHRI reference: 210847533 | 17.00 | 7.80 | 11100 | 1.94 | EPA 2481436 → |
XAFB36DXXN1+TXV+ furnace: TM9Y080B12MP11AHRI reference: 210847530 | 17.00 | 7.80 | 11000 | 1.96 | EPA 2481439 → |
XAFB36DBAN1+ furnace: TP9C060B12MP13AHRI reference: 210848693 | 17.00 | 7.80 | 11100 | 1.96 | EPA 2481452 → |
XAFA30DBAN1+ furnace: TL8E060A12UH11AHRI reference: 210848695 | 17.00 | 7.80 | 11100 | 1.96 | EPA 2481453 → |
XAFB36DBAN1+ furnace: TM8Y080B12MP11AHRI reference: 210849989 | 17.00 | 7.80 | 11000 | 1.98 | EPA 2481467 → |
XAFB36DBAN1+ furnace: TM9V080B12MP12AHRI reference: 210849991 | 17.00 | 7.80 | 10900 | 1.96 | EPA 2481470 → |
XAFB36DBAN1+ furnace: TM8V080B12MP12AHRI reference: 210850003 | 17.00 | 7.80 | 11100 | 1.96 | EPA 2481478 → |
XAFB36DXXN1+TXV+ furnace: TM8Y080B12MP11AHRI reference: 210851029 | 17.00 | 7.80 | 11000 | 1.98 | EPA 2481494 → |
XAFB36DBAN1+ furnace: TM9V060B12MP12AHRI reference: 210851028 | 17.00 | 7.80 | 11100 | 1.96 | EPA 2481495 → |
XAFB36DBAN1+ furnace: TM9E080B12MP12AHRI reference: 210851041 | 17.00 | 7.80 | 11100 | 1.98 | EPA 2481497 → |
XAFB36DBAN1+ furnace: TM9Y060B12MP11AHRI reference: 210845142 | 17.00 | 7.80 | 11000 | 1.96 | EPA 2486117 → |
XAFB36DXXN1+TXV+ furnace: TP9C060B12MP13AHRI reference: 210845145 | 17.00 | 7.80 | 11100 | 1.96 | EPA 2486119 → |
XAFB36DBAN1+EUE10AAHRI reference: 212956215 | 17.00 | 7.80 | 10900 | 2.02 | EPA 2649150 → |
XAFB36DBAN1+EBE12AAHRI reference: 212956214 | 17.00 | 7.80 | 10900 | 2.02 | EPA 2649151 → |
XAFB36DXXN1+EBE12A+TXVAHRI reference: 212956184 | 17.00 | 7.80 | 10900 | 2.02 | EPA 2649171 → |
XAFB36DXXN1+EUE10A+TXVAHRI reference: 212956185 | 17.00 | 7.80 | 10900 | 2.02 | EPA 2649173 → |
XAFB36DXXN1+EBE10A+TXVAHRI reference: 212956182 | 17.00 | 7.80 | 10900 | 2.02 | EPA 2649182 → |
XAFB36DBAN1+EBE10AAHRI reference: 212956212 | 17.00 | 7.80 | 10900 | 2.02 | EPA 2649227 → |
XAFB36DBAN1+EBE23AAHRI reference: 210848701 | 17.00 | 7.80 | 10900 | 2.02 | EPA 2649240 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.