HL19B3621
MOMENTUM
23 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HL19B3621. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 23 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 23 / 23 |
| EER2 · BTU/Wh | 11.7–12.5 | 23 / 23 |
| HSPF2 · BTU/Wh | 7.8 | 23 / 23 |
| Cooling capacity · BTU/h | 34,600–35,200 | 23 / 23 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,800–35,400 | 23 / 23 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,800–23,200 | 23 / 23 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,900–18,400 | 23 / 23 |
| COP at 5°F / −15°C | 1.8–2.06 | 23 / 23 |
| Equipment / loop type | HP - Split System | 23 / 23 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 23 / 23 |
| Compressor staging | Two-stage | 23 / 23 |
| Connected capability | No | 23 / 23 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHC60GBCN1+ furnace: TM8Y100C20MP11AHRI reference: 210846498 | 17.00 | 7.80 | 18000 | 1.96 | EPA 3557979 → |
XAHC60GBCN1+ furnace: TM8E120C20MP11AHRI reference: 210845172 | 17.00 | 7.80 | 18000 | 1.96 | EPA 3558041 → |
XAHC60GBCN1+ furnace: TM8Y120C20MP11AHRI reference: 210847544 | 17.00 | 7.80 | 18000 | 1.96 | EPA 3558053 → |
XAFC60GBCN1+ furnace: TM8Y100C20MP11AHRI reference: 210847548 | 17.00 | 7.80 | 18000 | 2.04 | EPA 3558054 → |
XAHC60GBCN1+ furnace: TMLE080C20MP11AHRI reference: 210847551 | 17.00 | 7.80 | 18300 | 1.96 | EPA 3558056 → |
XAHC60GBCN1+ furnace: TMLE100C20MP11AHRI reference: 210848952 | 17.00 | 7.80 | 18000 | 1.96 | EPA 3558077 → |
XAHC60GBCN1+ furnace: TM8E080C20MP11AHRI reference: 210848958 | 17.00 | 7.80 | 18300 | 1.96 | EPA 3558079 → |
XAHC60GBCN1+ furnace: TMLE120C20MP11AHRI reference: 210851286 | 17.00 | 7.80 | 18000 | 1.96 | EPA 3558083 → |
XAHC60GBCN1+ furnace: TM8E100C20MP11AHRI reference: 210850012 | 17.00 | 7.80 | 18000 | 1.96 | EPA 3558102 → |
XAFC60GBCN1+ furnace: TM8Y120C20MP11AHRI reference: 210850015 | 17.00 | 7.80 | 18000 | 2.04 | EPA 3558103 → |
XAFC60GBCN1+ furnace: Z8ET120C20LMPS1AHRI reference: 211769714 | 17.00 | 7.80 | 17900 | 1.80 | EPA 3990344 → |
XAFC60GBCN1+ furnace: TM8Y100C16MP11AHRI reference: 211725887 | 17.00 | 7.80 | 17900 | 2.04 | EPA 3990374 → |
XAFC60GBCN1+ furnace: TM8Y080C16MP11AHRI reference: 211725889 | 17.00 | 7.80 | 17900 | 2.04 | EPA 3990375 → |
XAFC60GBCN1+ furnace: TPLC100C20MP13AHRI reference: 211726156 | 17.00 | 7.80 | 18000 | 2.06 | EPA 3990381 → |
XAFC60GBCN1+ furnace: TPLC120C20MP13AHRI reference: 211726158 | 17.00 | 7.80 | 18000 | 2.06 | EPA 3990384 → |
XAFC60GBCN1+ furnace: TM8E120C20MP11AHRI reference: 210846494 | 16.00 | 7.80 | 18100 | 2.06 | EPA 3557978 → |
XAFC60GBCN1+ furnace: TMLE080C20MP11AHRI reference: 210845169 | 16.00 | 7.80 | 18000 | 2.06 | EPA 3558040 → |
XAFC60GBCN1+ furnace: TM8E080C20MP11AHRI reference: 210847543 | 16.00 | 7.80 | 18000 | 2.06 | EPA 3558052 → |
XAFC60GBCN1+ furnace: TMLE100C20MP11AHRI reference: 210847549 | 16.00 | 7.80 | 18000 | 2.06 | EPA 3558055 → |
XAFC60GBCN1+ furnace: TM8E100C20MP11AHRI reference: 210850016 | 16.00 | 7.80 | 18000 | 2.06 | EPA 3558104 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.