Johnson Controls / AIR-SOURCE HEAT PUMP

HH860E2S11

LX SERIES · source records, page 17

341 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity43,500–54,500BTU/h

Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 341 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19341 / 341
EER2 · BTU/Wh10–12341 / 341
HSPF2 · BTU/Wh8.1–9.5341 / 341
Cooling capacity · BTU/h43,500–54,500341 / 341
Heating capacity at 47°F / 8.3°C · BTU/h43,500–55,000341 / 341
Heating capacity at 17°F / −8.3°C · BTU/h31,800–39,000341 / 341
Heating capacity at 5°F / −15°C · BTU/h32,000–40,500341 / 341
COP at 5°F / −15°C2341 / 341
Equipment / loop typeHP - Split System341 / 341
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)341 / 341
Compressor stagingContinuously variable341 / 341
Connected capabilityNo341 / 341

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60D5XGS1+TXV+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 21637469017.009.00326002.00EPA 4047741
CTM60D5CGS1+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 21637473117.009.00326002.00EPA 4047767
CTM60C5CGS1+ furnace: Z8ET100C16LMPS1Cold climate designationAHRI reference: 21680186317.009.00326002.00EPA 4047890
CTF60C5CGS1+ furnace: Z8ET100C16LMPS1Cold climate designationAHRI reference: 21680186417.009.00326002.00EPA 4047891
CTU60C5XGS1+TXV+ furnace: Z8ET100C16LMPS1Cold climate designationAHRI reference: 21680186517.009.00326002.00EPA 4047892
CTF60C5CGS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 21680186617.009.00334002.00EPA 4047893
CTU60C5XGS1+TXV+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 21680186717.009.00334002.00EPA 4047894
CTM60C5CGS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 21680186817.009.50334002.00EPA 4047895
CTU60D5XGS1+TXVCold climate designationAHRI reference: 21733475915.208.50342002.00EPA 4469655
CTU60D5XHS1+TXVAHRI reference: 21733476915.208.10400002.00EPA 4469661
CTU60C5XGS1+TXVCold climate designationAHRI reference: 21733477115.208.50342002.00EPA 4469662
CTM60D5CGS1Cold climate designationAHRI reference: 21460653615.208.50342002.00EPA 4497295
CTF60C5CGS1Cold climate designationAHRI reference: 21460653415.208.50342002.00EPA 4497296
CTM60C5CGS1Cold climate designationAHRI reference: 21460653815.208.50342002.00EPA 4497297
CTM60C5CHS1AHRI reference: 21460653915.208.10400002.00EPA 4497298
CTF60D5CGS1Cold climate designationAHRI reference: 21460655515.208.50342002.00EPA 4497312
CTM60D5CHS1AHRI reference: 21460656315.208.10400002.00EPA 4497316
CTF60C5CHS1AHRI reference: 21460656515.208.10400002.00EPA 4497317
CTF60D5CHS1AHRI reference: 21460656115.208.10400002.00EPA 4497322
CTM60D5CJS1Cold climate designationAHRI reference: 21460652315.208.50400002.00EPA 4575836

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →