Heating performance & equipment details
Ranges include the 341 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 341 / 341 |
| EER2 · BTU/Wh | 10–12 | 341 / 341 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 341 / 341 |
| Cooling capacity · BTU/h | 43,500–54,500 | 341 / 341 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–55,000 | 341 / 341 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 341 / 341 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 341 / 341 |
| COP at 5°F / −15°C | 2 | 341 / 341 |
| Equipment / loop type | HP - Split System | 341 / 341 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 341 / 341 |
| Compressor staging | Continuously variable | 341 / 341 |
| Connected capability | No | 341 / 341 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CGS1+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 214397826 | 18.00 | 9.00 | 34000 | 2.00 | EPA 3739040 → |
CTM60C5CGS1+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 214397878 | 18.00 | 9.00 | 33600 | 2.00 | EPA 3739050 → |
CTM60C5CGS1+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 214397831 | 18.00 | 9.00 | 34000 | 2.00 | EPA 3739055 → |
CTF60C5CGS1+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 214398336 | 18.00 | 9.00 | 34400 | 2.00 | EPA 3739062 → |
CTF60C5CGS1+ furnace: TM9E100C16MP12Cold climate designationAHRI reference: 214398705 | 18.00 | 9.00 | 34400 | 2.00 | EPA 3739100 → |
CTF60C5CGS1+ furnace: TM9V100C20MP12Cold climate designationAHRI reference: 214398710 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3739105 → |
CTF60C5CGS1+ furnace: TP9C100C20MP13Cold climate designationAHRI reference: 214398715 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3739111 → |
CTF60C5CGS1+ furnace: Z9ES100C16SMPS1Cold climate designationAHRI reference: 214609145 | 18.00 | 9.00 | 34200 | 2.00 | EPA 3739125 → |
CTU60C5XGS1+TXV+ furnace: TL9E080C16UH11Cold climate designationAHRI reference: 214720030 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3739171 → |
CTU60C5XGS1+TXV+ furnace: TM8V120C20MP12Cold climate designationAHRI reference: 214719949 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3739190 → |
CTU60C5XGS1+TXV+ furnace: TMLV120C20MP12Cold climate designationAHRI reference: 214719959 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3739200 → |
CTU60C5XGS1+TXV+ furnace: TM8V100C20MP12Cold climate designationAHRI reference: 214719954 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3739203 → |
CTU60C5XGS1+TXV+ furnace: TM9V100C20MP12Cold climate designationAHRI reference: 214720198 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3739220 → |
CTU60C5XGS1+TXV+ furnace: TP9C100C20MP13Cold climate designationAHRI reference: 214720205 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3739227 → |
CTU60C5XGS1+TXV+ furnace: Z9ES100C16SMPS1Cold climate designationAHRI reference: 214720210 | 18.00 | 9.00 | 34200 | 2.00 | EPA 3739232 → |
CTU60C5XGS1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 214720133 | 18.00 | 9.00 | 34400 | 2.00 | EPA 3740301 → |
CTU60C5XGS1+TXV+ furnace: TM9E100C16MP12Cold climate designationAHRI reference: 214719980 | 18.00 | 9.00 | 34400 | 2.00 | EPA 3740335 → |
CTM60C5CGS1+ furnace: Z8VT100C16SMPC1Cold climate designationAHRI reference: 217444061 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044942 → |
CTU60C5XGS1+TXV+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 217444063 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044943 → |
CTF60C5CGS1+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 217444062 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044944 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.