Johnson Controls / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 9

355 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19355 / 355
EER2 · BTU/Wh10–12355 / 355
HSPF2 · BTU/Wh8.1–9.5355 / 355
Cooling capacity · BTU/h31,600–35,000355 / 355
Heating capacity at 47°F / 8.3°C · BTU/h30,400–35,000355 / 355
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600355 / 355
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200355 / 355
COP at 5°F / −15°C2–2.1355 / 355
Equipment / loop typeHP - Split System355 / 355
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)355 / 355
Compressor stagingContinuously variable355 / 355
Connected capabilityNo355 / 355

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 21745505219.009.00232002.00EPA 4048386
JHC36C5CD2SS1Cold climate designationAHRI reference: 21439539919.009.00252002.10EPA 4514615
CTM36B5CDS1+JMC12B2SN1Cold climate designationAHRI reference: 21439768318.009.00248002.00EPA 3437714
CTM36C5CDS1+ furnace: Z8ES100C16SMPS1Cold climate designationAHRI reference: 21458471518.008.50260002.00EPA 3438093
CTF36C5CDS1+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 21458467518.008.50258002.00EPA 3438108
CTM36C5CDS1+ furnace: Z8ES080C16SMPS1Cold climate designationAHRI reference: 21458471018.008.50254002.00EPA 3438121
CTF36B5CDS1+ furnace: Z8ES100B12SMPS1Cold climate designationAHRI reference: 21458462518.008.50250002.00EPA 3438138
CTM36C5CDS1+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 21458474518.008.50258002.00EPA 3438209
CTF36C5CDS1+ furnace: Z8ES080C16SMPS1Cold climate designationAHRI reference: 21458468018.008.50254002.00EPA 3438225
CTF36B5CDS1+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21458459518.008.50248002.00EPA 3438261
CTF36C5CDS1+ furnace: Z8ES100C16SMPS1Cold climate designationAHRI reference: 21458456018.008.50260002.00EPA 3438272
CTM36B5CDS1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 21439682418.008.50250002.00EPA 3558516
CTM36B5CDS1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 21439682918.008.50250002.00EPA 3558599
CTM36B5CDS1+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 21439849018.008.50256002.00EPA 3558765
CTU36B5XDS1+TXV+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21480776518.008.50248002.00EPA 3559586
CTU36B5XDS1+TXV+ furnace: Z8ES100B12SMPS1Cold climate designationAHRI reference: 21480777518.008.50250002.00EPA 3559596
CTF36C5CDS1+ furnace: TL9E080C16UH11Cold climate designationAHRI reference: 21439689018.008.50260002.00EPA 3713717
CTF36C5CDS1+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 21439681918.008.50264002.00EPA 3713736
CTM36C5CDS1+ furnace: TM9Y100C16MP11Cold climate designationAHRI reference: 21439639018.009.00252002.00EPA 3713746
CTF36B5CDS1+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 21439691018.008.50256002.00EPA 3713792

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →