Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 355 / 355 |
| EER2 · BTU/Wh | 10–12 | 355 / 355 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 355 / 355 |
| Cooling capacity · BTU/h | 31,600–35,000 | 355 / 355 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,400–35,000 | 355 / 355 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 355 / 355 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 355 / 355 |
| COP at 5°F / −15°C | 2–2.1 | 355 / 355 |
| Equipment / loop type | HP - Split System | 355 / 355 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 355 / 355 |
| Compressor staging | Continuously variable | 355 / 355 |
| Connected capability | No | 355 / 355 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF48C5CFS1+ furnace: Z8ES080C16LMPS1Cold climate designationAHRI reference: 216783348 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4008877 → |
CTU48C5XFS1+TXV+ furnace: Z8ES080C16LMPS1Cold climate designationAHRI reference: 216783363 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4008881 → |
CTM48C5CFS1+ furnace: Z8ES080C16LMPS1Cold climate designationAHRI reference: 216783378 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4008886 → |
CTF36C5CDS1+ furnace: Z8ES080C20LMPS1Cold climate designationAHRI reference: 216783423 | 19.00 | 8.50 | 27000 | 2.00 | EPA 4008925 → |
CTM48C5CFS1+ furnace: Z8ES080C20LMPS1Cold climate designationAHRI reference: 216784854 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4008952 → |
CTF48C5CFS1+ furnace: Z8ES100C20LMPS1Cold climate designationAHRI reference: 216785663 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4008962 → |
CTU48C5XFS1+TXV+ furnace: Z8ES100C20LMPS1Cold climate designationAHRI reference: 216785678 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4008967 → |
CTF48C5CFS1+ furnace: Z8ES120C16LMPS1Cold climate designationAHRI reference: 216784165 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4008979 → |
CTU48C5XFS1+TXV+ furnace: Z8ES120C16LMPS1Cold climate designationAHRI reference: 216784180 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4008984 → |
CTF48C5CFS1+ furnace: Z8ES120C20LMPS1Cold climate designationAHRI reference: 216784313 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4008989 → |
CTU48C5XFS1+TXV+ furnace: Z8ES120C20LMPS1Cold climate designationAHRI reference: 216784329 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4008994 → |
CTM48C5CFS1+ furnace: Z8ES120C16LMPS1Cold climate designationAHRI reference: 216785931 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4008996 → |
CTM36C5CDS1+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 217444074 | 19.00 | 8.50 | 23400 | 2.00 | EPA 4044954 → |
CTM36C5CDS1+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 217444076 | 19.00 | 9.00 | 23400 | 2.00 | EPA 4044957 → |
CTU48C5XFS1+TXV+ furnace: Z8VT100C16SMPC1Cold climate designationAHRI reference: 217444085 | 19.00 | 9.00 | 23000 | 2.00 | EPA 4044984 → |
CTF48C5CFS1+ furnace: Z8VT100C16SMPC1Cold climate designationAHRI reference: 217444084 | 19.00 | 9.00 | 23000 | 2.00 | EPA 4044985 → |
CTF48C5CFS1+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 217444086 | 19.00 | 9.00 | 23000 | 2.00 | EPA 4044986 → |
CTU48C5XFS1+TXV+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 217444087 | 19.00 | 9.00 | 23000 | 2.00 | EPA 4044987 → |
CTM48C5CFS1+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 217444088 | 19.00 | 9.00 | 22600 | 2.00 | EPA 4044988 → |
CTM48C5CFS1+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 217444089 | 19.00 | 9.50 | 22600 | 2.00 | EPA 4044989 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →