HH836E2S11
LX SERIES · source records, page 5
355 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 355 / 355 |
| EER2 · BTU/Wh | 10–12 | 355 / 355 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 355 / 355 |
| Cooling capacity · BTU/h | 31,600–35,000 | 355 / 355 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,400–35,000 | 355 / 355 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 355 / 355 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 355 / 355 |
| COP at 5°F / −15°C | 2–2.1 | 355 / 355 |
| Equipment / loop type | HP - Split System | 355 / 355 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 355 / 355 |
| Compressor staging | Continuously variable | 355 / 355 |
| Connected capability | No | 355 / 355 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU48C5XFS1+TXV+ furnace: Z8ES100C16SMPS1Cold climate designationAHRI reference: 214720230 | 19.00 | 9.00 | 25200 | 2.00 | EPA 3714766 → |
CTU36B5XDS1+JMET12BS2N1+TXVCold climate designationAHRI reference: 214779458 | 19.00 | 9.00 | 25800 | 2.00 | EPA 3714815 → |
CTU48C5XFS1+TXV+ furnace: TM9E100C16MP12Cold climate designationAHRI reference: 214720138 | 19.00 | 9.00 | 25400 | 2.00 | EPA 3714820 → |
CTU48C5XFS1+TXV+ furnace: Z8ES100C20SMPS1Cold climate designationAHRI reference: 214720143 | 19.00 | 9.00 | 25400 | 2.00 | EPA 3714825 → |
CTU48C5XFS1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 214719990 | 19.00 | 9.00 | 25400 | 2.00 | EPA 3714902 → |
CTU48C5XFS1+TXV+ furnace: Z8ES080C20SMPS1Cold climate designationAHRI reference: 214719929 | 19.00 | 9.00 | 25400 | 2.00 | EPA 3714935 → |
CTU48C5XFS1+JMET12CS2N1+TXVCold climate designationAHRI reference: 214720047 | 19.00 | 9.00 | 25200 | 2.00 | EPA 3714943 → |
CTU48C5XFS1+TXV+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 214720052 | 19.00 | 9.00 | 25200 | 2.00 | EPA 3714947 → |
CTU48C5XFS1+TXV+ furnace: Z8ES120C20SMPS1Cold climate designationAHRI reference: 214720020 | 19.00 | 9.00 | 25400 | 2.00 | EPA 3714977 → |
CTU48C5XFS1+JME12C2SN1+TXVCold climate designationAHRI reference: 215853318 | 19.00 | 9.00 | 25200 | 2.00 | EPA 3715182 → |
CTU48C5XFS1+JMET16CS2N1+TXVCold climate designationAHRI reference: 215853317 | 19.00 | 9.00 | 25200 | 2.00 | EPA 3715183 → |
CTU48C5XFS1+JMC16C2SN1+TXVCold climate designationAHRI reference: 215853319 | 19.00 | 9.00 | 25200 | 2.00 | EPA 3715184 → |
JHE36B5CD2SS1Cold climate designationAHRI reference: 215853322 | 19.00 | 9.00 | 26000 | 2.00 | EPA 3715186 → |
CTM36C5CDS1+JMVT17CC2N1Cold climate designationAHRI reference: 215853321 | 19.00 | 9.00 | 25800 | 2.00 | EPA 3715187 → |
CTM36C5CDS1+JMC16C2SN1Cold climate designationAHRI reference: 215853324 | 19.00 | 9.00 | 25800 | 2.00 | EPA 3715188 → |
CTM36C5CDS1+JME12C2SN1Cold climate designationAHRI reference: 215853323 | 19.00 | 9.00 | 24800 | 2.00 | EPA 3715189 → |
CTM36C5CDS1+JMET12CS2N1Cold climate designationAHRI reference: 215853325 | 19.00 | 9.00 | 25600 | 2.00 | EPA 3715190 → |
CTM36C5CDS1+JME16C2SN1Cold climate designationAHRI reference: 215853326 | 19.00 | 9.00 | 24800 | 2.00 | EPA 3715191 → |
CTM36C5CDS1+JMET16CS2N1Cold climate designationAHRI reference: 215853327 | 19.00 | 9.00 | 25600 | 2.00 | EPA 3715192 → |
CTM36C5CDS1+JMVT16CC2N1Cold climate designationAHRI reference: 215853329 | 19.00 | 9.00 | 25800 | 2.00 | EPA 3715193 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →