Johnson Controls / AIR-SOURCE HEAT PUMP

HH824E2S11

LX SERIES · source records, page 4

182 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity23,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 182 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19182 / 182
EER2 · BTU/Wh11–12182 / 182
HSPF2 · BTU/Wh8.5–9.5182 / 182
Cooling capacity · BTU/h23,000182 / 182
Heating capacity at 47°F / 8.3°C · BTU/h23,000182 / 182
Heating capacity at 17°F / −8.3°C · BTU/h17,100–18,900182 / 182
Heating capacity at 5°F / −15°C · BTU/h17,200–19,400182 / 182
COP at 5°F / −15°C2182 / 182
Equipment / loop typeHP - Split System182 / 182
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)182 / 182
Compressor stagingContinuously variable182 / 182
Connected capabilityNo182 / 182

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30B5ACS1+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21458470018.009.50184002.00EPA 3438230
CTM30B5ACS1+ furnace: Z8ES100B12SMPS1Cold climate designationAHRI reference: 21458457518.009.50194002.00EPA 3438241
CTU30B5XCS1+JMET08BS2N1+TXVCold climate designationAHRI reference: 21480781018.009.50182002.00EPA 3559331
CTU30B5XCS1+JMVT12BC2N1+TXVCold climate designationAHRI reference: 21480781518.009.50190002.00EPA 3559336
CTU30B5XCS1+JMC12B2SN1+TXVCold climate designationAHRI reference: 21480782018.009.50190002.00EPA 3559341
CTM36B5ADS1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 21480773818.009.50188002.00EPA 3559559
CTM36B5ADS1+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21480774318.009.50185002.00EPA 3559564
CTM36B5ADS1+ furnace: TMLE080B12MP11Cold climate designationAHRI reference: 21480768918.009.50186002.00EPA 3559784
CTU30B5XCS1+JMET12BS2N1+TXVCold climate designationAHRI reference: 21480783018.009.50185002.00EPA 3559856
CTM36B5ADS1+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21481023518.009.50185002.00EPA 3560020
CTM36B5ADS1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 21481023718.009.50188002.00EPA 3560023
CTM36B5ADS1+ furnace: TM8E080B12MP11Cold climate designationAHRI reference: 21481024318.009.50186002.00EPA 3560027
CTM30B5ACS1+ furnace: Z9ES080B12SMPS1Cold climate designationAHRI reference: 21460909618.009.50191002.00EPA 3714649
CTU30B5XCS1+TXV+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21465164318.009.50191002.00EPA 3714832
CTU30B5XCS1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21465197518.009.50184002.00EPA 3714879
CTM30B5ACS1+JMET08BS2N1Cold climate designationAHRI reference: 21585331518.009.50181002.00EPA 3715179
CTM30B5ACS1+JMET12BS2N1Cold climate designationAHRI reference: 21585331418.009.50184002.00EPA 3715180
CTM30B5ACS1+JMVT12BC2N1Cold climate designationAHRI reference: 21585331618.009.50190002.00EPA 3715181
CTM36B5ADS1+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 21591224918.009.50184002.00EPA 3723388
CTM36B5ADS1+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 21591222818.009.50185002.00EPA 3723402

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.