Johnson Controls / AIR-SOURCE HEAT PUMP

HH824E2S11

LX SERIES · source records, page 2

182 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity23,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 182 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19182 / 182
EER2 · BTU/Wh11–12182 / 182
HSPF2 · BTU/Wh8.5–9.5182 / 182
Cooling capacity · BTU/h23,000182 / 182
Heating capacity at 47°F / 8.3°C · BTU/h23,000182 / 182
Heating capacity at 17°F / −8.3°C · BTU/h17,100–18,900182 / 182
Heating capacity at 5°F / −15°C · BTU/h17,200–19,400182 / 182
COP at 5°F / −15°C2182 / 182
Equipment / loop typeHP - Split System182 / 182
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)182 / 182
Compressor stagingContinuously variable182 / 182
Connected capabilityNo182 / 182

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU36B5XDS1+JMC12B2SN1+TXVCold climate designationAHRI reference: 21480770419.009.50185002.00EPA 3559800
CTU36B5XDS1+JME08B2SN1+TXVCold climate designationAHRI reference: 21480770919.009.50180002.00EPA 3559807
CTU36B5XDS1+JMET12BS2N1+TXVCold climate designationAHRI reference: 21480771419.009.50181002.00EPA 3559812
CTU36B5XDS1+JME12B2SN1+TXVCold climate designationAHRI reference: 21480771919.009.50185002.00EPA 3559819
CTU30B5XCS1+JME12B2SN1+TXVCold climate designationAHRI reference: 21480782519.009.50190002.00EPA 3559845
CTU36B5XDS1+TXV+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21465107219.009.50186002.00EPA 3714790
CTU36B5XDS1+TXV+ furnace: Z8ES100B12SMPS1Cold climate designationAHRI reference: 21465151319.009.50188002.00EPA 3714800
CTM36B5ADS1+JME12B2SN1Cold climate designationAHRI reference: 21601073419.009.50184002.00EPA 3737559
CTM36B5ADS1+JME08B2SN1Cold climate designationAHRI reference: 21601073919.009.50180002.00EPA 3737564
CTM36B5ADS1+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21601074919.009.50186002.00EPA 3737574
CTF30A5ADS1+ furnace: Z9ES060A10SMPS1Cold climate designationAHRI reference: 21460916019.009.00185002.00EPA 3739129
CTU36B5XDS1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21465062619.009.50186002.00EPA 3739254
JHE36B5AD2SS1Cold climate designationAHRI reference: 21601329619.009.50185002.00EPA 3740367
CTU36B5XDS1+TXV+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 21678219419.009.50186002.00EPA 4008793
CTF36B5ADS1+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 21678217919.009.50186002.00EPA 4008836
CTF36B5ADS1+ furnace: Z8ES100B12LMPS1Cold climate designationAHRI reference: 21678349719.009.50188002.00EPA 4008930
CTU36B5XDS1+TXV+ furnace: Z8ES100B12LMPS1Cold climate designationAHRI reference: 21678351119.009.50188002.00EPA 4008935
CTF36B5ADS1+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21744409719.009.50182002.00EPA 4044997
CTM36B5ADS1+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21744409919.009.50182002.00EPA 4044998
CTU36B5XDS1+TXV+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21744409819.009.50182002.00EPA 4045000

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.