GE / AIR-SOURCE HEAT PUMP

NS17H36SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 2

324 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,200–36,000BTU/h

Each efficiency range summarizes published EPA records for NS17H36SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 324 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8324 / 324
EER2 · BTU/Wh12.2–14324 / 324
HSPF2 · BTU/Wh7.8–8.7324 / 324
Cooling capacity · BTU/h35,200–36,000324 / 324
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000324 / 324
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000324 / 324
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300324 / 324
COP at 5°F / −15°C2.08–2.34324 / 324
Equipment / loop typeHP - Split System324 / 324
Refrigerant / source-reported GWPR-410A (GWP:2088)324 / 324
Compressor stagingSingle stage324 / 324
Connected capabilityNo324 / 324

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC51CT4+TDR+ furnace: NF96U110S5C-*AHRI reference: 21026239716.408.00175002.22EPA 2454977
NCUC50/60CT4+TDR+ furnace: NF80U110T5C-*AHRI reference: 21026243216.407.80171002.16EPA 2455366
NCHC51CT4+TDR+ furnace: NF80X100V5C-*AHRI reference: 21026239816.408.10178002.22EPA 2460015
NCUU36BP4+TDR+TXV+ furnace: NF80X080V4B-*AHRI reference: 21026236816.408.00170002.16EPA 2461111
NCUC36BT4+TDR+ furnace: NF80X080V4B-*AHRI reference: 21026242416.408.00170002.16EPA 2461286
NCHC51CT4+TDR+ furnace: NF80U110S5C-*AHRI reference: 21026239516.408.10174002.18EPA 2461342
NCUU36BP4+TDR+TXV+ furnace: NF80U090T4B-*AHRI reference: 21026236216.407.80170002.14EPA 2461787
NCUC50/60CT4+TDR+ furnace: NF80U090S5C-*AHRI reference: 21026243616.407.80170002.12EPA 2462054
NCUC36BT4+TDR+ furnace: NF80U090T4B-*AHRI reference: 21026241816.407.80170002.14EPA 2462307
NCHC42CT5D-**+TDR+ furnace: NF95X100S5C*AHRI reference: 21749124616.408.00178002.18EPA 4431946
NCHC42CT5D-**+TDR+ furnace: NF80L110S5C*AHRI reference: 21749098116.408.10180002.20EPA 4431975
NCHC51CT5D-**+TDR+ furnace: NF80L110S5C*AHRI reference: 21749098216.408.10174002.18EPA 4431976
NCHC42CT5D-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21749110816.408.10180002.20EPA 4431982
NCHC51CT5D-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21749110916.408.10174002.18EPA 4431983
NCUC50CT5D-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21749107316.407.80170002.12EPA 4432030
NCHC51CT5D-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21749120316.408.10178002.22EPA 4432911
NCHC51CT5D-**+TDR+ furnace: NF96U110S5C*AHRI reference: 21749133916.408.00175002.22EPA 4432917
NCUC36BT5D-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21749109216.407.80170002.14EPA 4432972
NCHC42CT5D-**+TDR+ furnace: NF96U090S4C*AHRI reference: 21749131716.408.00181002.20EPA 4433083
NCUC50CT5D-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21749112216.407.80171002.16EPA 4433126

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →