GE / AIR-SOURCE HEAT PUMP

NS17H36SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 3

324 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,200–36,000BTU/h

Each efficiency range summarizes published EPA records for NS17H36SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 324 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8324 / 324
EER2 · BTU/Wh12.2–14324 / 324
HSPF2 · BTU/Wh7.8–8.7324 / 324
Cooling capacity · BTU/h35,200–36,000324 / 324
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000324 / 324
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000324 / 324
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300324 / 324
COP at 5°F / −15°C2.08–2.34324 / 324
Equipment / loop typeHP - Split System324 / 324
Refrigerant / source-reported GWPR-410A (GWP:2088)324 / 324
Compressor stagingSingle stage324 / 324
Connected capabilityNo324 / 324

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC48CT5D-**+TDR+ furnace: NF97U110M5C*AHRI reference: 21749144016.407.80172002.14EPA 4433186 →
NCHC42BT5D-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21749106316.408.10183002.28EPA 4433201 →
NCHC42BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749119116.408.10184002.28EPA 4433209 →
NCHC42BT5D-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21749097416.408.10183002.28EPA 4433216 →
NCUC36BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749119316.408.00170002.16EPA 4433256 →
NCUC48CT5D-**+TDR+ furnace: NF97X080V4C*AHRI reference: 21749147716.407.80170002.12EPA 4433276 →
NCHC42CT5D-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21749107016.408.00179002.20EPA 4433295 →
NCHC42CT5D-**+TDR+ furnace: NF97U090M4C*AHRI reference: 21749141716.408.00180002.20EPA 4433310 →
NCUC48CT5D-**+TDR+ furnace: NF97U090M4C*AHRI reference: 21749141916.407.80170002.12EPA 4433312 →
NAM42V1TA4AHRI reference: 21164162716.208.10174002.22EPA 2454671 →
NCUC50/60CT4+TDR+ furnace: NF96U090S4C-*AHRI reference: 21026243816.207.80172002.12EPA 2454973 →
NCHC51CT4+TDR+ furnace: NF97U090M4C-*AHRI reference: 21026240316.208.00174002.16EPA 2454981 →
NCUC50/60CT4+TDR+ furnace: NF80U110S5C-*AHRI reference: 21026243716.207.80173002.12EPA 2455026 →
NCUU36BP4+TDR+TXV+ furnace: NF80U090V4B-*AHRI reference: 21026236916.207.80172002.14EPA 2455063 →
NCHC48BT4+TDR+ furnace: NF80U090T4B-*AHRI reference: 21026237616.208.00172002.20EPA 2455074 →
NCUC36BT4+TDR+ furnace: NF80U090V4B-*AHRI reference: 21026242516.207.80172002.14EPA 2455220 →
NCUC36BT4+TDR+ furnace: NF80U070S3B-*AHRI reference: 21026242116.207.80172002.14EPA 2455232 →
NCHC51CT4+TDR+ furnace: NF96U090S4C-*AHRI reference: 21026239616.208.00175002.18EPA 2455253 →
NCUU36AP4+TDR+TXV+ furnace: NF80X060V3A-*AHRI reference: 21026235716.207.80172002.14EPA 2457561 →
NCHC48BT4+TDR+ furnace: NF80U090S4B-*AHRI reference: 21026238016.208.00172002.24EPA 2457577 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →