GE / AIR-SOURCE HEAT PUMP

NS17H36SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series

324 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,200–36,000BTU/h

Each efficiency range summarizes published EPA records for NS17H36SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 324 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8324 / 324
EER2 · BTU/Wh12.2–14324 / 324
HSPF2 · BTU/Wh7.8–8.7324 / 324
Cooling capacity · BTU/h35,200–36,000324 / 324
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000324 / 324
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000324 / 324
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300324 / 324
COP at 5°F / −15°C2.08–2.34324 / 324
Equipment / loop typeHP - Split System324 / 324
Refrigerant / source-reported GWPR-410A (GWP:2088)324 / 324
Compressor stagingSingle stage324 / 324
Connected capabilityNo324 / 324

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC48CT5D-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21749112116.808.00170002.18EPA 4433125
NCUC48CT5D-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21749107216.807.80168002.14EPA 4433297
NCHC51CT4+TDR+ furnace: NF80U090S5C-*AHRI reference: 21026239416.608.00174002.22EPA 2455006
NCUC36BT4+TDR+ furnace: NF80U090S4B-*AHRI reference: 21026242216.607.80168002.14EPA 2455013
NCHC51CT4+TDR+ furnace: NF80U110T5C-*AHRI reference: 21026239016.608.10175002.24EPA 2459975
NCUU36BP4+TDR+TXV+ furnace: NF80U090S4B-*AHRI reference: 21026236616.607.80168002.14EPA 2462007
NCDC48CT4+TDR+ furnace: NF80D110S5C-*AHRI reference: 21335584116.608.70188002.34EPA 2841276
NCUC48CT5D-**+TDR+ furnace: NF95X100S5C*AHRI reference: 21749124816.607.80170002.16EPA 4431948
NCUC48CT5D-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21749111016.608.00170002.14EPA 4431984
NCUC48CT5D-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21749120416.608.00171002.14EPA 4432912
NCHC42CT5D-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21749120216.608.10184002.22EPA 4432913
NCUC48CT5D-**+TDR+ furnace: NF96U110S5C*AHRI reference: 21749134016.607.80170002.18EPA 4432918
NCDC48CT5D-**+TDR+ furnace: NF80D110S5C*AHRI reference: 21749093116.608.70188002.34EPA 4432991
NCUC48CT5D-**+TDR+ furnace: NF96U090S4C*AHRI reference: 21749131916.607.80170002.16EPA 4433084
NCHC42CT5D-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21749111916.608.10181002.24EPA 4433178
NCHC51CT5D-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21749112016.608.10175002.24EPA 4433179
NCUC36BT5D-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21749097616.607.80168002.14EPA 4433218
NCUC36BT5D-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21749106516.607.80168002.14EPA 4433290
NCHC51CT5D-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21749107116.608.00174002.22EPA 4433296
NCHC42CT5D-**+TDR+ furnace: NF96U110S5C*AHRI reference: 21749133816.608.00178002.20EPA 4433355

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.