GE / AIR-SOURCE HEAT PUMP

NS17H18SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 9

257 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for NS17H18SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8257 / 257
EER2 · BTU/Wh12.2–14257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h18,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100257 / 257
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700257 / 257
COP at 5°F / −15°C1.9–2.16257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC24AT5D-**+TDR+ furnace: NF80L070S3A*AHRI reference: 21749094316.408.0082002.10EPA 4433372 →
NCHC24BT5D-**+TDR+ furnace: NF96U045V3B*AHRI reference: 21749127716.408.1084002.06EPA 4433378 →
NCUC24AT4+TDR+ furnace: NF80U045S3A-*AHRI reference: 21026197416.208.0082002.08EPA 2455058 →
NCUU24AP4+TDR+TXV+ furnace: NF80U045S3A-*AHRI reference: 21026188716.208.0082002.08EPA 2461546 →
NCDC3036BT4+TDR+ furnace: NF96D070S4B-*AHRI reference: 21335581216.208.4090002.08EPA 2841291 →
NCDC3036BT4+TDR+ furnace: NF97D070M3B-*AHRI reference: 21335581316.208.5091002.08EPA 2841292 →
NCDC36BT5D-**+TDR+ furnace: NF97D070M3B*AHRI reference: 21749135416.208.5091002.08EPA 4431997 →
NCUC24AT5D-**+TDR+ furnace: NF80L045S3A*AHRI reference: 21749093416.208.0082002.08EPA 4433000 →
NCUC24AT5D-**+TDR+ furnace: NF80U045S3A*AHRI reference: 21749099116.208.0082002.08EPA 4433070 →
NCDC36BT5D-**+TDR+ furnace: NF96D070S4B*AHRI reference: 21749125416.208.4090002.08EPA 4433357 →
NAM24E1TA4AHRI reference: 21164161516.008.1085002.14EPA 2454672 →
NCUU24AP4+TDR+TXV+ furnace: NF80U070V3A-*AHRI reference: 21026189116.008.1085002.06EPA 2454951 →
NCUU24BP4+TDR+TXV+ furnace: NF95X060S3B-*AHRI reference: 21026189416.008.0082002.04EPA 2454988 →
NCUU30AP4+TDR+TXV+ furnace: NF80U045T3A-*AHRI reference: 21026190916.007.8079001.98EPA 2454995 →
NCUC24BT4+TDR+ furnace: NF95X040S3B-*AHRI reference: 21026198016.008.0082002.06EPA 2455012 →
NCUC24BT4+TDR+ furnace: NF96U070S3B-*AHRI reference: 21026198816.008.0082002.08EPA 2455017 →
NCHC24BT4+TDR+ furnace: NF96U070S3B-*AHRI reference: 21026194916.008.1082002.06EPA 2455059 →
NCUU24BP4+TDR+TXV+ furnace: NF96U045S3B-*AHRI reference: 21026190016.008.0082002.04EPA 2455061 →
NCUC24AT4+TDR+ furnace: NF80U070V3A-*AHRI reference: 21026197816.008.1085002.06EPA 2455075 →
NCHC24AT4+TDR+ furnace: NF80X060S3A-*AHRI reference: 21026193216.007.8081002.00EPA 2455106 →