GE / AIR-SOURCE HEAT PUMP

NS17H18SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 8

257 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for NS17H18SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8257 / 257
EER2 · BTU/Wh12.2–14257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h18,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100257 / 257
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700257 / 257
COP at 5°F / −15°C1.9–2.16257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC30AT5D-**+TDR+ furnace: NF80L070S3A*AHRI reference: 21749094416.407.8077001.98EPA 4433043
NCHC24BT5D-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21749102016.408.1082002.10EPA 4433047
NCUC24BT5D-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21749102216.408.0082002.10EPA 4433049
NCHC24AT5D-**+TDR+ furnace: NF80U045S3A*AHRI reference: 21749099016.408.0080002.06EPA 4433069
NCHC24BT5D-**+TDR+ furnace: NF80L070S3B*AHRI reference: 21749095216.408.1082002.10EPA 4433078
NCUC30BT5D-**+TDR+ furnace: NF80U090V4B*AHRI reference: 21749109716.408.0080001.96EPA 4433086
NCUC24BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749118316.408.1086002.12EPA 4433108
NCHC24BT5D-**+TDR+ furnace: NF97U045V3B*AHRI reference: 21749136816.408.1084002.06EPA 4433117
NCHC24BT5D-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21749139416.408.1084002.10EPA 4433132
NCUC24BT5D-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21749139616.408.1084002.08EPA 4433134
NCHC24BT5D-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21749146116.408.1084002.08EPA 4433150
NCUC24BT5D-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21749146316.408.1084002.06EPA 4433152
NCUC30BT5D-**+TDR+ furnace: NF96U045V3B*AHRI reference: 21749128016.408.0078002.00EPA 4433194
NCHC24BT5D-**+TDR+ furnace: NF96U070V3B*AHRI reference: 21749130316.408.1084002.10EPA 4433225
NCHC24BT5D-**+TDR+ furnace: NF97U070M3B*AHRI reference: 21749138116.408.1084002.10EPA 4433231
NCUC24BT5D-**+TDR+ furnace: NF97U070M3B*AHRI reference: 21749138316.408.1084002.08EPA 4433264
NCHC24BT5D-**+TDR+ furnace: NF95X060S3B*AHRI reference: 21749122616.408.1082002.06EPA 4433299
NCUC30BT5D-**+TDR+ furnace: NF95X060S3B*AHRI reference: 21749122916.407.8077002.00EPA 4433301
NCHC24BT5D-**+TDR+ furnace: NF97X040V3B*AHRI reference: 21749144816.408.1084002.08EPA 4433332
NCUC24BT5D-**+TDR+ furnace: NF97X040V3B*AHRI reference: 21749145016.408.1084002.06EPA 4433334

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.