GE / AIR-SOURCE HEAT PUMP

NS17H18SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 10

257 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for NS17H18SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8257 / 257
EER2 · BTU/Wh12.2–14257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h18,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100257 / 257
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700257 / 257
COP at 5°F / −15°C1.9–2.16257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC24BT4+TDR+ furnace: NF80U090V4B-*AHRI reference: 21026195116.008.1087002.08EPA 2455131
NCUC24AT4+TDR+ furnace: NF80U045T3A-*AHRI reference: 21026197216.008.1084002.06EPA 2455150
NCUC24BT4+TDR+ furnace: NF95X060S3B-*AHRI reference: 21026198116.008.0082002.04EPA 2455152
NAM18V1TA4AHRI reference: 21072047716.008.1082002.08EPA 2456559
NCHC24AT4+TDR+ furnace: NF80U070V3A-*AHRI reference: 21026193916.008.1087002.04EPA 2457336
NAM24V2TA4AHRI reference: 21067785416.008.3082002.16EPA 2458248
NCUU30AP4+TDR+TXV+ furnace: NF80X040S3A-*AHRI reference: 21026190716.007.8075001.92EPA 2459964
NCHC24AT4+TDR+ furnace: NF80X040S3A-*AHRI reference: 21026193116.007.8081002.00EPA 2459971
NCUU30AP4+TDR+TXV+ furnace: NF80X060S3A-*AHRI reference: 21026190816.007.8075001.92EPA 2460005
NCUC30AT4+TDR+ furnace: NF80X060S3A-*AHRI reference: 21026199516.007.8075001.92EPA 2460011
NCUC24BT4+TDR+ furnace: NF80U090V4B-*AHRI reference: 21026199016.008.1085002.06EPA 2460020
NCUU24AP4+TDR+TXV+ furnace: NF80U045T3A-*AHRI reference: 21026188516.008.1084002.06EPA 2460257
NCUU24BP4+TDR+TXV+ furnace: NF80U090V4B-*AHRI reference: 21026190316.008.1085002.06EPA 2460804
NCUC30AT4+TDR+ furnace: NF80X040S3A-*AHRI reference: 21026199416.007.8075001.92EPA 2461528
NCHC24BT4+TDR+ furnace: NF95X040S3B-*AHRI reference: 21026194116.008.1082002.06EPA 2461531
NCUU24BP4+TDR+TXV+ furnace: NF95X040S3B-*AHRI reference: 21026189316.008.0082002.06EPA 2461761
NCHC24AT4+TDR+ furnace: NF80U045T3A-*AHRI reference: 21026193316.008.1082002.02EPA 2461782
NCUU24BP4+TDR+TXV+ furnace: NF96U070S3B-*AHRI reference: 21026190116.008.0082002.08EPA 2461790
NCUC24BT4+TDR+ furnace: NF96U045S3B-*AHRI reference: 21026198716.008.0082002.04EPA 2462294
NCHC24BT4+TDR+ furnace: NF96U045S3B-*AHRI reference: 21026194816.008.1082002.06EPA 2462297

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →