Heating performance & equipment details
Ranges include the 386 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.3 | 386 / 386 |
| EER2 · BTU/Wh | 10–12 | 386 / 386 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 386 / 386 |
| Cooling capacity · BTU/h | 32,200–36,200 | 386 / 386 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 386 / 386 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 386 / 386 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,600–30,800 | 386 / 386 |
| COP at 5°F / −15°C | 1.8–1.95 | 386 / 386 |
| Equipment / loop type | HP - Split System | 386 / 386 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 386 / 386 |
| Compressor staging | Continuously variable | 386 / 386 |
| Connected capability | No | 386 / 386 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC37CT5****+TDR+ furnace: NF98U090M3C***Cold climate designationAHRI reference: 218079600 | 18.00 | 8.50 | 28200 | 1.85 | EPA 4569722 → |
NCUC37CT5****+TDR+ furnace: NF97X080V5C***Cold climate designationAHRI reference: 218079599 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4569723 → |
NCUC36AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 217124067 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4003543 → |
NCHC30AT5****+TDR+ furnace: NF80X060S3A***Cold climate designationAHRI reference: 217124091 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4003566 → |
NCHC30AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 217124090 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4003567 → |
NCHC30AT5****+TDR+ furnace: NF80U070S3A***Cold climate designationAHRI reference: 217124095 | 17.95 | 9.00 | 28200 | 1.90 | EPA 4003571 → |
NCHC30BT5****+TDR+ furnace: NF80U070S3B***Cold climate designationAHRI reference: 217124098 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4003574 → |
NCHC30BT5****+TDR+ furnace: NF80L070S3B***Cold climate designationAHRI reference: 217124099 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4003576 → |
NCHC36BT5****+TDR+ furnace: NF80U070S3B***Cold climate designationAHRI reference: 217124121 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4003596 → |
NCHC36BT5****+TDR+ furnace: NF80L070S3B***Cold climate designationAHRI reference: 217124122 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4003598 → |
NCHC36CT5****+TDR+ furnace: NF98U090M4C***Cold climate designationAHRI reference: 217124135 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4003611 → |
NCUC30BT5****+TDR+ furnace: NF80U070V4BF***Cold climate designationAHRI reference: 217313478 | 17.95 | 8.10 | 29200 | 1.80 | EPA 4028785 → |
NCHC30AT5****+TDR+ furnace: NF80U070S3AF***Cold climate designationAHRI reference: 217313544 | 17.95 | 9.00 | 28200 | 1.90 | EPA 4028814 → |
NCDC42BT5****+TDR+ furnace: NF93D070S3BF***Cold climate designationAHRI reference: 217313704 | 17.95 | 9.00 | 28200 | 1.90 | EPA 4028939 → |
NCUU37CT5****+TDR+ furnace: NF80X100V5C***Cold climate designationAHRI reference: 218079626 | 17.95 | 8.50 | 28200 | 1.85 | EPA 4569696 → |
NCUC37CT5****+TDR+ furnace: NF80X100V5C***Cold climate designationAHRI reference: 218079595 | 17.95 | 8.50 | 28200 | 1.85 | EPA 4569727 → |
NCHC36CT5****+TDR+ furnace: NF97X080V4C***Cold climate designationAHRI reference: 216743589 | 17.90 | 9.00 | 28400 | 1.90 | EPA 3893287 → |
NCUC36AT5****+TDR+ furnace: NF80X060S3A***Cold climate designationAHRI reference: 217124068 | 17.90 | 8.50 | 28400 | 1.85 | EPA 4003544 → |
NCUC36AT5****+TDR+ furnace: NF80U070S3A***Cold climate designationAHRI reference: 217124072 | 17.90 | 8.50 | 28400 | 1.85 | EPA 4003547 → |
NCDC42BT5****+TDR+ furnace: NF80D070S3B***Cold climate designationAHRI reference: 217124143 | 17.90 | 9.00 | 28200 | 1.90 | EPA 4003619 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.