| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.3 | 386 / 386 |
| EER2 · BTU/Wh | 10–12 | 386 / 386 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 386 / 386 |
| Cooling capacity · BTU/h | 32,200–36,200 | 386 / 386 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 386 / 386 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 386 / 386 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,600–30,800 | 386 / 386 |
| COP at 5°F / −15°C | 1.8–1.95 | 386 / 386 |
| Equipment / loop type | HP - Split System | 386 / 386 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 386 / 386 |
| Compressor staging | Continuously variable | 386 / 386 |
| Connected capability | No | 386 / 386 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC36BT5****+TDR+ furnace: NF96U030S3BF***Cold climate designationAHRI reference: 217313513 | 17.90 | 8.50 | 28600 | 1.85 | EPA 4028830 → |
NCHC30AT5****+TDR+ furnace: NF80U070V3AF***Cold climate designationAHRI reference: 217313551 | 17.90 | 9.00 | 28200 | 1.90 | EPA 4028836 → |
NCUC36AT5****+TDR+ furnace: NF80U070S3AF***Cold climate designationAHRI reference: 217313486 | 17.90 | 8.50 | 28400 | 1.85 | EPA 4028843 → |
NCUU37CT5****+TDR+ furnace: NF97U090V5C***Cold climate designationAHRI reference: 218079611 | 17.90 | 8.50 | 28200 | 1.85 | EPA 4569711 → |
NCUC37CT5****+TDR+ furnace: NF97U090V5C***Cold climate designationAHRI reference: 218079580 | 17.90 | 8.50 | 28200 | 1.85 | EPA 4569742 → |
NAS42E1TB5****Cold climate designationAHRI reference: 218635941 | 17.90 | 9.40 | 29600 | 1.90 | EPA 4661151 → |
NCDC42BT5****+TDR+ furnace: NF96D045S3B***Cold climate designationAHRI reference: 217124145 | 17.85 | 9.00 | 28200 | 1.90 | EPA 4003621 → |
NCHC30AT5****+TDR+ furnace: NF80U030V3AF***Cold climate designationAHRI reference: 217313546 | 17.85 | 9.00 | 28400 | 1.90 | EPA 4028815 → |
NCHC36BT5****+TDR+ furnace: NF96U030S3BF***Cold climate designationAHRI reference: 217313629 | 17.85 | 8.50 | 28600 | 1.85 | EPA 4028904 → |
NCU[C,U]36CT5****+TDR+ furnace: NF97U110V4CF***Cold climate designationAHRI reference: 217663206 | 17.85 | 8.50 | 28400 | 1.85 | EPA 4498196 → |
NCUU37CT5****+TDR+ furnace: NF98U090M5C***Cold climate designationAHRI reference: 218079633 | 17.85 | 8.50 | 28400 | 1.85 | EPA 4569689 → |
NCUU37CT5****+TDR+ furnace: NF98U090M4C***Cold climate designationAHRI reference: 218079632 | 17.85 | 8.50 | 28200 | 1.85 | EPA 4569690 → |
NCUU37CT5****+TDR+ furnace: NF97U090V4CF***Cold climate designationAHRI reference: 218079610 | 17.85 | 8.50 | 28200 | 1.85 | EPA 4569712 → |
NCUC37CT5****+TDR+ furnace: NF98U090M5C***Cold climate designationAHRI reference: 218079602 | 17.85 | 8.50 | 28400 | 1.85 | EPA 4569720 → |
NCUC37CT5****+TDR+ furnace: NF98U090M4C***Cold climate designationAHRI reference: 218079601 | 17.85 | 8.50 | 28200 | 1.85 | EPA 4569721 → |
NCUC37CT5****+TDR+ furnace: NF97U090V4CF***Cold climate designationAHRI reference: 218079579 | 17.85 | 8.50 | 28200 | 1.85 | EPA 4569743 → |
NCUC36BT5****+TDR+ furnace: NF98U070M3B***Cold climate designationAHRI reference: 217124077 | 17.80 | 8.50 | 28200 | 1.85 | EPA 4003552 → |
NCUC36BT5****+TDR+ furnace: NF97U045T3BF***Cold climate designationAHRI reference: 217313508 | 17.80 | 8.50 | 28600 | 1.85 | EPA 4028818 → |
NCUC36AT5****+TDR+ furnace: NF80U030V3AF***Cold climate designationAHRI reference: 217313489 | 17.80 | 8.50 | 28400 | 1.85 | EPA 4028844 → |
NCUC36AT5****+TDR+ furnace: NF80U070V3AF***Cold climate designationAHRI reference: 217313493 | 17.80 | 8.50 | 28400 | 1.85 | EPA 4028846 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →