NS18H36HA5***
Connect · source records, page 4
386 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS18H36HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 386 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.3 | 386 / 386 |
| EER2 · BTU/Wh | 10–12 | 386 / 386 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 386 / 386 |
| Cooling capacity · BTU/h | 32,200–36,200 | 386 / 386 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 386 / 386 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 386 / 386 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,600–30,800 | 386 / 386 |
| COP at 5°F / −15°C | 1.8–1.95 | 386 / 386 |
| Equipment / loop type | HP - Split System | 386 / 386 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 386 / 386 |
| Compressor staging | Continuously variable | 386 / 386 |
| Connected capability | No | 386 / 386 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCHC30BT5****+TDR+ furnace: NF80U090V4B***Cold climate designationAHRI reference: 217124105 | 18.05 | 8.50 | 28200 | 1.85 | EPA 4003581 → |
NCHC36BT5****+TDR+ furnace: NF80U090V4B***Cold climate designationAHRI reference: 217124128 | 18.05 | 8.50 | 28200 | 1.85 | EPA 4003604 → |
NCUC36BT5****+TDR+ furnace: NF93U030S3BF***Cold climate designationAHRI reference: 217313515 | 18.05 | 8.50 | 28600 | 1.85 | EPA 4028829 → |
NCHC30BT5****+TDR+ furnace: NF80U090V3BF***Cold climate designationAHRI reference: 217313554 | 18.05 | 8.50 | 28400 | 1.85 | EPA 4028837 → |
NCHC30BT5****+TDR+ furnace: NF80L090V4BF***Cold climate designationAHRI reference: 217313586 | 18.05 | 8.50 | 28200 | 1.85 | EPA 4028885 → |
NCHC36BT5****+TDR+ furnace: NF80L090V4BF***Cold climate designationAHRI reference: 217313641 | 18.05 | 8.50 | 28200 | 1.85 | EPA 4028910 → |
NAM36V1TA5****Cold climate designationAHRI reference: 215869481 | 18.00 | 9.50 | 30000 | 1.80 | EPA 3716598 → |
NAM42E1TA5****Cold climate designationAHRI reference: 216604750 | 18.00 | 9.00 | 30000 | 1.90 | EPA 3892998 → |
NCHC36CT5****+TDR+ furnace: NF97U090V3C***Cold climate designationAHRI reference: 216743588 | 18.00 | 9.00 | 28400 | 1.90 | EPA 3893286 → |
NCUC36AT5****+TDR+ furnace: NF80U045S3A***Cold climate designationAHRI reference: 217124073 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4003548 → |
NCUC36AT5****+TDR+ furnace: NF80L045S3A***Cold climate designationAHRI reference: 217124074 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4003550 → |
NCHC36CT5****+TDR+ furnace: NF96U090V3C***Cold climate designationAHRI reference: 217177714 | 18.00 | 9.00 | 28400 | 1.90 | EPA 4006873 → |
NAM42E3TA5****Cold climate designationAHRI reference: 216705364 | 18.00 | 9.40 | 29000 | 1.90 | EPA 4028696 → |
NCHC30BT5****+TDR+ furnace: NF80U070V3BF***Cold climate designationAHRI reference: 217313558 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4028838 → |
NCHC30BT5****+TDR+ furnace: NF93U030S3BF***Cold climate designationAHRI reference: 217313574 | 18.00 | 8.50 | 28600 | 1.85 | EPA 4028880 → |
NCHC36BT5****+TDR+ furnace: NF80U090V3BF***Cold climate designationAHRI reference: 217313610 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4028896 → |
NCHC36BT5****+TDR+ furnace: NF80U070V3BF***Cold climate designationAHRI reference: 217313615 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4028898 → |
NAM30V2TA5****Cold climate designationAHRI reference: 217738985 | 18.00 | 9.50 | 29600 | 1.90 | EPA 4511833 → |
NCUU37CT5****+TDR+ furnace: NF98U090M3C***Cold climate designationAHRI reference: 218079631 | 18.00 | 8.50 | 28200 | 1.85 | EPA 4569691 → |
NCUU37CT5****+TDR+ furnace: NF97X080V5C***Cold climate designationAHRI reference: 218079630 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4569692 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.