Fraser-Johnston / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 19

454 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17454 / 454
EER2 · BTU/Wh11–12454 / 454
HSPF2 · BTU/Wh8–8.5454 / 454
Cooling capacity · BTU/h32,800–36,000454 / 454
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200454 / 454
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800454 / 454
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800454 / 454
COP at 5°F / −15°C2–2.5454 / 454
Equipment / loop typeHP - Split System454 / 454
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)454 / 454
Compressor stagingTwo-stage454 / 454
Connected capabilityNo454 / 454

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36B5CDS1+ furnace: TP9C080B12MP13AHRI reference: 21799368515.208.10180002.00EPA 4514732 →
CTM36B5CDS1+ furnace: TM9V060B12MP12AHRI reference: 21799370115.208.10180002.00EPA 4514750 →
CTM36B5CDS1+ furnace: TP9C060B12MP13AHRI reference: 21799371415.208.10180002.00EPA 4514781 →
CTM36C5CDS1+ furnace: TM9V080C16MP12AHRI reference: 21799373015.208.10180002.00EPA 4514796 →
CTM36C5CDS1+ furnace: TP9C080C16MP13AHRI reference: 21799374215.208.10180002.00EPA 4514808 →
CTF36B5CDS1+ furnace: TM9V080B12MP12AHRI reference: 21799376015.208.10180002.00EPA 4514827 →
CTF36B5CDS1+ furnace: TP9C080B12MP13AHRI reference: 21799377115.208.10180002.00EPA 4514829 →
CTU36B5XDS1+TXV+ furnace: TM9V080B12MP12AHRI reference: 21799378815.208.10180002.00EPA 4514880 →
CTU36B5XDS1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21799380115.208.10180002.00EPA 4514890 →
CTF36C5CDS1+ furnace: TM9V100C20MP12AHRI reference: 21799381915.208.10180002.00EPA 4514903 →
CTF36C5CDS1+ furnace: TP9C100C20MP13AHRI reference: 21799383115.208.10180002.00EPA 4514911 →
CTF36C5CDS1+ furnace: TM9V080C16MP12AHRI reference: 21799391515.208.10176002.00EPA 4514926 →
CTF36C5CDS1+ furnace: TP9C080C16MP13AHRI reference: 21799392015.208.10176002.00EPA 4514931 →
CTM36C5CDS1+ furnace: TM9V100C16MP12AHRI reference: 21799392715.208.10180002.00EPA 4514940 →
CTM36C5CDS1+ furnace: TP9C100C16MP13AHRI reference: 21799393215.208.10180002.00EPA 4514941 →
CTF36C5CDS1+ furnace: TM9V100C16MP12AHRI reference: 21799393915.208.10180002.00EPA 4514950 →
CTF36C5CDS1+ furnace: TP9C100C16MP13AHRI reference: 21799394415.208.10180002.00EPA 4514955 →
CTU36B5XDS1+TXV+ furnace: TP9C060B12MP13AHRI reference: 21799390815.208.10180002.00EPA 4514983 →
CTM36C5CDS1+ furnace: TM9V100C20MP12AHRI reference: 21799385115.208.10180002.00EPA 4515055 →
CTM36C5CDS1+ furnace: TP9C100C20MP13AHRI reference: 21799386615.208.10180002.00EPA 4515062 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →