XH636E2S11
LX SERIES · source records, page 18
454 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 454 / 454 |
| EER2 · BTU/Wh | 11–12 | 454 / 454 |
| HSPF2 · BTU/Wh | 8–8.5 | 454 / 454 |
| Cooling capacity · BTU/h | 32,800–36,000 | 454 / 454 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 454 / 454 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,000–23,800 | 454 / 454 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,600–19,800 | 454 / 454 |
| COP at 5°F / −15°C | 2–2.5 | 454 / 454 |
| Equipment / loop type | HP - Split System | 454 / 454 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 454 / 454 |
| Compressor staging | Two-stage | 454 / 454 |
| Connected capability | No | 454 / 454 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU48C5XFS2+TXV+ furnace: TM9V100C20MP12AHRI reference: 218527999 | 16.00 | 8.10 | 18600 | 2.00 | EPA 4647899 → |
CTF48C5CFS2+ furnace: TP9C100C20MP13AHRI reference: 218527993 | 16.00 | 8.10 | 18600 | 2.00 | EPA 4647905 → |
CTF48C5CFS2+ furnace: TM9V100C20MP12AHRI reference: 218527989 | 16.00 | 8.10 | 18600 | 2.00 | EPA 4647909 → |
CTU48C5XFS2+TXV+ furnace: TP9C100C16MP13AHRI reference: 218527983 | 16.00 | 8.10 | 18600 | 2.00 | EPA 4647915 → |
CTU48C5XFS2+TXV+ furnace: TM9V100C16MP12AHRI reference: 218527979 | 16.00 | 8.10 | 18600 | 2.00 | EPA 4647919 → |
CTF48C5CFS2+ furnace: TP9C100C16MP13AHRI reference: 218527973 | 16.00 | 8.10 | 18600 | 2.00 | EPA 4647925 → |
CTM36C5CDS2+JME16C2SN2AHRI reference: 218638141 | 16.00 | 8.10 | 18400 | 2.36 | EPA 4664462 → |
CTM48C5CFS2+JME16C2SN2AHRI reference: 218638135 | 16.00 | 8.10 | 19000 | 2.46 | EPA 4664468 → |
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 218638129 | 16.00 | 8.10 | 18600 | 2.36 | EPA 4664474 → |
CTF36B5CDS2+JME12B2SN2AHRI reference: 218638123 | 16.00 | 8.10 | 18600 | 2.36 | EPA 4664480 → |
CTM48C5CFS2+JME12C2SN2AHRI reference: 218638093 | 16.00 | 8.50 | 19300 | 2.44 | EPA 4664510 → |
CTF36C5CDS2+JME12C2SN2AHRI reference: 218638087 | 16.00 | 8.10 | 18800 | 2.36 | EPA 4664516 → |
CTM36C5CDS2+JME12C2SN2AHRI reference: 218638081 | 16.00 | 8.10 | 18400 | 2.36 | EPA 4664522 → |
CTF36C5CDS2+JME16C2SN2AHRI reference: 218638075 | 16.00 | 8.10 | 18400 | 2.36 | EPA 4664528 → |
CTU36B5XDS1+TXV+ furnace: Z9ES080B12SMPS1AHRI reference: 217017283 | 15.20 | 8.10 | 18600 | 2.30 | EPA 4013028 → |
CTF36B5CDS1+ furnace: Z9ES080B12SMPS1AHRI reference: 217017281 | 15.20 | 8.10 | 18600 | 2.30 | EPA 4013029 → |
CTU36B5XDS1+TXV+ furnace: Z9ET080B12SMPS1AHRI reference: 217017345 | 15.20 | 8.10 | 18700 | 2.30 | EPA 4013147 → |
CTF36B5CDS1+ furnace: Z9ET080B12SMPS1AHRI reference: 217017346 | 15.20 | 8.10 | 18700 | 2.30 | EPA 4013151 → |
CTM36B5CDS1+ furnace: Z8VT080B12SMPC1AHRI reference: 217445269 | 15.20 | 8.10 | 18600 | 2.32 | EPA 4045326 → |
CTM36B5CDS1+ furnace: TM9V080B12MP12AHRI reference: 217993674 | 15.20 | 8.10 | 18000 | 2.00 | EPA 4514719 → |