XH548E2S11
LX SERIES · source records, page 9
355 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 355 / 355 |
| EER2 · BTU/Wh | 11–12 | 355 / 355 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 355 / 355 |
| Cooling capacity · BTU/h | 44,500–48,000 | 355 / 355 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 355 / 355 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,200 | 355 / 355 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,000 | 355 / 355 |
| COP at 5°F / −15°C | 2.1–2.42 | 355 / 355 |
| Equipment / loop type | HP - Split System | 355 / 355 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 355 / 355 |
| Compressor staging | Two-stage | 355 / 355 |
| Connected capability | No | 355 / 355 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60D5CGS1+ furnace: Z8ES130D20LMPS1AHRI reference: 216784232 | 15.20 | 7.80 | 25400 | 2.24 | EPA 4572186 → |
CTM60C5CGS1+ furnace: Z8ES080C20LMPS1AHRI reference: 216783779 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4572191 → |
CTM60C5CHS1+ furnace: Z8ES080C16LMPS1AHRI reference: 216783621 | 15.20 | 8.00 | 26000 | 2.40 | EPA 4572206 → |
CTM60C5CGS1+ furnace: Z8ES100C20LMPS1AHRI reference: 216783462 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4572211 → |
CTF60C5CHS1+ furnace: Z8ES080C20LMPS1AHRI reference: 216782348 | 15.20 | 7.80 | 26000 | 2.36 | EPA 4572221 → |
CTM60C5CGS1+ furnace: Z8ET100C20LMPS1AHRI reference: 216437688 | 15.20 | 7.80 | 25400 | 2.28 | EPA 4572226 → |
CTM60C5CGS1+ furnace: Z8ET120C20LMPS1AHRI reference: 216437653 | 15.20 | 7.80 | 26000 | 2.26 | EPA 4572231 → |
CTU60D5XGS1+TXV+ furnace: Z9ET120D20SMPS1AHRI reference: 216376962 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4572237 → |
CTF60D5CGS1+ furnace: Z9ET120D20SMPS1AHRI reference: 216376933 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4572240 → |
CTU60C5XGS1+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 215743085 | 15.20 | 7.80 | 26000 | 2.26 | EPA 4572247 → |
CTF60C5CGS1+ furnace: Z8ET120C20LMPS1AHRI reference: 215743067 | 15.20 | 7.80 | 26000 | 2.26 | EPA 4572250 → |
CTU60C5XGS1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 214808103 | 15.20 | 7.80 | 25800 | 2.20 | EPA 4572281 → |
CTU60C5XGS1+TXV+ furnace: Z8ES100C20SMPS1AHRI reference: 214808093 | 15.20 | 7.80 | 25400 | 2.24 | EPA 4572286 → |
CTU60C5XGS1+JMC16C2SN1+TXVAHRI reference: 214807979 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4572291 → |
CTU60C5XGS1+JMVT16CC2N1+TXVAHRI reference: 214807974 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4572296 → |
CTU60C5XGS1+JMET16CS2N1+TXVAHRI reference: 214807918 | 15.20 | 7.80 | 25200 | 2.24 | EPA 4572301 → |
CTU60C5XGS1+JMC17C2SN1+TXVAHRI reference: 214807913 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4572306 → |
CTU60C5XGS1+JMVT17CC2N1+TXVAHRI reference: 214807908 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4572311 → |
CTU60D5XHS1+TXV+ furnace: TP9C120D20MP13AHRI reference: 214649976 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4572323 → |
CTU60D5XHS1+TXV+ furnace: TM9V120D20MP12AHRI reference: 214649960 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4572328 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →